Feces Specimen FOB Test Kit 50ng/Ml Cut - Off 24 Months Shelf Life CE Approval

Brand Name:New Life
Certification:ISO13485,CE
Minimum Order Quantity:5000pcs
Delivery Time:20-30days
Payment Terms:T/T, Western Union
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang
Address: 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

High Accuracy Tumor Mark FOB Rapid Test Strip, for detecting Fecal Occult Blood in Feces, gold colloidal method


Product Name: One Step FOB Rapid Diagnostic Test Strip / Fecal Occult Blood Rapid Diagnostic Test Strip


ProductCat NoSpecimenFormatKit Size
Tumor Markers Tests
FOBYT304S3Feces50/25/40/200ng/mlStrip100T/BOX
YT304C450/25/40/200ng/mlCassette25T/BOX

INTENDED USE:


The FOB Rapid Test Dipstick (Feces) is a rapid chromatographic immunoassay for the qualitative detection of Human Occult Blood in feces.


TEST PRINCIPLE:


The FOB Rapid Test Dipstick (Feces) is a qualitative, lateral flow immunoassay for the detection of Human Occult Blood in feces. The membrane is precoated with anti-hemoglobin antibody on the test line region of the test. During testing, the specimen reacts with the particle coated with anti-hemoglobin antibody. The mixture migrates upward on the membrane chromatographically by capillary action to react with anti-hemoglobin antibody on the membrane and generate a colored line. The presence of this colored line in the test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region, indicating that the proper volume of specimen has been added and membrane wicking has occurred.


SPECIMEN COLLECTION AND STORAGE


1. Collect stool specimen by using the sample collection tube provided.


2. Unscrew the top of the sample collection tube, take out the sample collection stick and collect the specimen by dipping the stick into 3 different places of the stool specimen.


3. Replace the stick in the sample collection tube and screw tightly.


If the specimen cannot be tested on the day of collection, store the stool specimen at 2-8℃. Bring the specimen to room temperature before testing.


TEST PROCEDURE


1. To collect fecal specimens: Collect sufficient quantity of feces (1-2 mL or 1-2 g) in a clean, dry specimen collection container to obtain maximum antigens (if present). Best results will be obtained if the assay is performed within 6 hours after collection. Specimen collected may be stored for 3 days at 2-8℃ if not tested within 6 hours. For long term storage, specimens should be kept below -20℃.


2. To process fecal specimens:


For Solid Specimens:

Unscrew the cap of the specimen collection tube,then randomly stab the specimen collection applicator into the fecal specimen in at least 3 different sites to collect approximately 50 mg of feces (equivalent to 1/4 of a pea). Do not scoop the fecal specimen.


For Liquid Specimens:

Hold the dropper vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 80 μL) into the specimen collection tube containing the extraction buffer.


3. Bring the pouch to room temperature before opening it. Remove the test dipstick from the foil pouch and use it as soon as possible. Best results will be obtained if the test is performed immediately after opening the foil pouch.


4. Fix the reaction tube, hold the specimen collection tube upright and break off the tip of the specimen collection tube. Invert the specimen collection tube and transfer 8-10 full drops of the extracted specimen (approx. 500μL) to the reaction tube, then with arrows pointing toward the exaction buffer, immerse the dipstick and start the timer. Do not immerse the dipstick past the maximum line. See illustration below.


5. Read results at 5 minutes. Do not read results after 10 minutes.


INTERPRETATION OF RESULTS


Positive: Two colored lines appears in the result window, one in the test region and another one in the control region. This indicates a positive result no matter the test line is stronger or weaker than the control line.


Negative: Only the control line appears in the result window. This indicates a negative test result.


Invalid: If the control line does not appear, the test results are invalid regardless of the presence or absence of the test line.



PERFORMANCE CHARACTERS:


The FOB Rapid Test Dipstick (Feces) has been compared with another leading commercial rapid test using clinical specimens.


MethodOther Rapid TestTotal Result

FOB Rapid Test Dipstick

(Feces)

ResultsPositiveNegative
Positive1894193
Negative10802812
Total Result1998061005

Relative sensitivity: 95.0% (95%CI*: 91.0%~97.6%);


Relative specificity: 99.5% (95%CI*: 98.7%~99.9%);


Accuracy: 98.6% (95%CI*: 97.4%~99.0%). *Confidence Intervals


Sensitivity: The FOB Rapid Test Dipstick (Feces) can detect levels of Fecal Occult Blood as low as 50 ng/mL or 6 μg/g feces.


ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry
China Feces Specimen FOB Test Kit 50ng/Ml Cut - Off 24 Months Shelf Life CE Approval supplier

Feces Specimen FOB Test Kit 50ng/Ml Cut - Off 24 Months Shelf Life CE Approval

Inquiry Cart 0