Add to Cart
Touch Screen IEC60695-11-5 / IEC60695-2-2 Needle Flame Tester, Flammability Testing Equipment
Description:
Needle flame tester adopts full cold plate electrostatic high-grade
paint outer box; using the current advanced embedded computer
control, to achieve full intelligent control.
The needle flame test is to use a needle burner of the specified
size (Φ0.9mm), with a specific gas (butane or propane), and the
sample is fired at a 45° angle. The sample and the ignition mat are
cited. Burning time and burning length are used to assess the risk
of ignition of small flames inside the equipment due to fault
conditions.
Needle flame tester is applicable to GB4706.1, GB8898.1, GB4943.1,
GB7000.1, GB4793.1 and other standards, such as lighting,
low-voltage electrical appliances, household appliances, machine
tools, electrical machinery, electric tools, electronic
instruments, electrical instruments The research, production and
quality inspection departments of electrical and electronic
equipment such as information technology equipment, electrical
affairs equipment, electrical connectors and accessories, as well
as components and components thereof, are also applicable to
insulating materials, engineering plastics or other solid
combustible materials industries.
Standards:
GB4706.1-1998
GB5169.5-2008
IEC60695-2-2
IEC60695-11-5
Feature:
1, The character of test equipment: burning box and the main
mechanical parts is made of stainless steel what is good looking,
smoke resistance corrosion. The Control system has a higher degree
automation, imported key components , digital time,
three-dimensional adjustable fixture, automatic control of test
procedures, independent ventilation, easily used observation and
recording, stable and reliable.
2, test box shell and important parts is made of stainless steel,
smoke resistant, gas corrosion. The control system has a high
degree of automation and automatic ignition function. Temperature
and time are digital displayed, easy to observe and record. The
control system is stable and reliable.
Specification:
Control method | Adopt current advanced embedded computer control to achieve full intelligent control mode |
Display | Color LCD display, operation interface, new version software upgrade |
Burner | Stainless steel, inner hole Φ 0.5mm ± 0.1mm, outer diameter ≤Φ0.9mm, length ≥ 35mm |
Burner angle | Can be vertical (when adjusting and measuring flame height) and tilting 45° (at test) |
Ignition bedding layer | 10mm thick white pine board, covering 12g/m2 ~ 30g/m2 standard silk paper, 200mm ± 5mm from the flame application |
Gas | 95% butane gas, or propane gas |
Gas flame temp gradient | 100℃ ± 2℃~ 700℃ ± 3℃ ( room temperature~ 999℃ ) |
Temp measure time | 23.5s±1.0s(1s ~ 999.9s can be adjustable) |
Flame height | 12mm ± 1mm (adjustable) |
Application flame time | 5s,10s,20s,30s,60s, 120s-1+0s (1s ~ 999.9s digital display can be preset) |
Flame time | 1s ~ 999.9s( digital display, can pause by manual ) |
Test Volume | ≥ 0.5m 3 |
Temp sensor | Ø0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstand Temperature -40°C~ 1100°C |
Dimension | W 1250mm × D 600mm × H 1150mm ,exhaust hole Φ 100mm ; |
Power | 220V 0.5kVA |