Add to Cart
Professional IEC 60331 Line and Cable Fire Resistance Testing Equipment
Introduction:
Fire Resistance Tester is used in test conditions where the basic
flame temperature is at least 750ºC and tests the cable exposed to
the flame that needs to maintain the circuit integrity.
Standard:
IEC 60331 - Test for electric cables under fir conditions - Circuit
integrity
IEC 60331 Part 11 - Apparatus - Fire alone at a flame temperature
of at least 750˚C
IEC 60331 Part 21 - Procedures and requirements - Cables of rated
voltage up to and including 0.6/1kV
KWS 409 : Wire of Fire Resistance (Fire-Resistence) - 5.14 Fire
resistance test
Specification:
1. Test Chamber Size : (W) 1,600 * (D) 500 * (H) 500
2. Heat Source : Ribbon type Propane Gas Burner
3. Burner Dimension : (L) 500 x (W) 10 mm / Space of hole : 3.2mm
4. Flame Failure device, Control thermocouples
5. Pilot feed, Gas flow, Rotameter-type flowmeters
6. Auto Ignition system
7. Mass Flow Controller
8. Gas : 15 SLPM / Signal Output : 0 ~ 5V / Accuracy : ±1 % fo F.S
9. Air : 180 SLPM / Signal Output : 0 ~ 5V / Accuracy : ±1 % fo F.S
10. Electric Control : Transformer & Slidacs : 3 Phase 3 wire,
100~1,000V
11. DAQ System
12. 16 channel Analog Input / Output, 200ks/s
13. 16 channel Digital Input / Output
14. Control Rack : (W) 730 x (D) 650 x (H) 1,400 / 19" Rack / Each
Assembly Connector
Features:
1. The burner has a Ventury Mixer structure and it's a ribbon type
propane gas burner with a front length of 500mm
2. Structured with 3 rows of cross holes, Average front width of
burner: 15mm, Hole diameter: 1.32mm, Distance between the center:
3.2mm.
3. Allows a polished hole row in pilot hole for flame preservation
in both faces of Burner plate
4. A sample support is fixed with a clamp on the side to avoid
movement and the other side allows heat spread in length.
5. The central part of the cable is approx. 300mm separated and
it's supported by two metal rings. Besides the 2 metal rings there
are other ground connected parts.
6. The internal diameter of sample support ring is approx. 150mm
made of metal, round shape with a 10±2mm diameter.
7. The front of Burner position is located to be at least 200mm
from chamber floor or at least 300mm from chamber's wall surface.
8. The horizontal axis of burner is located 70±10mm downwards from
lowest part of sample cable and vertical axis of burner is located
approx. 45mm from the vertical axis.
9. Two thermocouple(A,B) are horizontally installed separated 45mm
left and right of burner center-line to check if ignition input is
within 750+50ºC.
10. Add for KWA 409(Korea Wire Shipbuilding Industry Cooperative)
of Fire resistance test(options)
11. It has 2 type of mode which manual mode by control panel and
auto mode by computer software.
Before order, user can select it. It is customizing. And if order
IEC 60331-11,12 and BS 6387, user can use one Slidacs
system(various up to 1,000V power supplier). Cost should be down.