RS485 50/60Hz PV Hybrid Solar Inverter DSP Grid With Lithium Battery

Brand Name:CONSNANT
Certification:CE(EN62109); EN61000; C2
Model Number:HT4830S80-145 | HT4840S80-145 | HT4850S80-145 | HT4825U80-145 | HT4830U80-145 | HT4835U80-145
Minimum Order Quantity:20 Pieces
Delivery Time:5-8 days for sample order, 15-21 days for large quantity
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Building B6, Junfeng Industrial Park, Fuyong Town, Bao'an District, Shenzhen City, 518103 P.R.China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Mutiple Mode Hybrid PV Energy Storage Grid Solar Inverter


Product Instruction:


HT series is a new hybrid PV energy storage inverter controller integrating PV energy storage,mains charging

and storage and AC sine wave output. Using DSP control through advanced control algorithms, it comes with high

response speed, high reliability, high industrialization standard and other characteristics.

Four charging modes are available: only PV, mains priority, PV priority, and hybrid charging by mains & PV;

two output modes: inverter and mains are available to meet different application needs.


Specification Reference:

ModelHT4830S80-145HT4840S80-145HT4850S80-145HT4825U80-145HT4830U80-145HT4835U80-145
Mains mode
Rated input voltage220/230Vac110/120Vac
Input voltage range(170Vac~280Vac) ±2%
(90Vac-280Vac)±2%
(90Vac~140Vac) ±2%
Frequency range47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz);
Conversion time10ms (typical)
(bypass and inverter)
Maximum bypass overload current40A
Inverter mode
Output voltage waveformPure sine wave
Rated output power (VA)3000(2600/2700
/3000)
4000(3480/360
3800/4000)
5000(4350/4500
/4800/5000)
2500(2000/2180
/2290)
3000(2500/2600
/2750)
3500(2900/3000
/3200)
Rated output power (W)3000(2600/2700
/3000)
4000(3480/360
3800/4000)
5000(4350/4500
/4800/5000)
2500(2000/2180
/2290)
3000(2500/2600
/2750)
3500(2900/3000
/3200)
Rated output voltage (Vac)230Vac(200/208/220/240Vac Settable)120Vac(100/105/110Vac Settable)
Output voltage error±5%
Output frequency range (Hz)50Hz ± 0.3Hz
60Hz ± 0.3Hz
Efficiency>92%>91%
Overload protection(102%<load<125%) ±10%: Report error and turn off output after 5 minutes;
(125%<load<150%) ±10%: Report error and turn off output after 10 seconds;
Load>150% ±10%: Report error and turn off output after 5 seconds;
(102%<load<110%) ±10%: Report error and turn off output after 5 minutes;
(110%<load<125%) ±10%: Report error and turn off output after 10 seconds;
Load>125% ±10%: Report error and turn off output after 5 seconds;
Peak power6000VA8000VA10000VA4000VA4500VA5000VA
Loaded motor capacity2HP3HP4HP1HP2HP2HP
Bypass circuit breaker specification63A
Rated battery input voltage48V (minimum starting voltage 44V)
Battery voltage range40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery...LCD screen can be set)
Eco modeLoad ””≤ 50W
AC charging
Maximum charge current0-60A0-40A
Charge
current error
± 5Adc
Charge voltage range40 - 58Vdc40 - 60Vdc
Circuit breaker specification(AC IN) 63A/(BAT) 125A
PC charge
Maximum PV open circuit voltage145Vdc
PV operating voltage range60-145Vdc
MPPT voltage range60-115Vdc
Battery voltage range40-60Vdc
Maximum output power4200W
PV charge current range (settable)0-80A
Charge short circuit protectionBAT circuit breaker and fuse
Wiring protectionReverse polarity protection
Hybrid charging Max charger current specifications (AC charger+PV charger)
Max charger current(can be set)0-140A0-120A
Certified specification
Specification certificationCE(EN62109)
EMC certification levelEN61000, C2
Operating temperature range-15°C to 55°C
Storage temperature range-25°C ~ 60°C
RH range5% to 95% (conformal coating protection)
Noise≤60dB
Heat dissipationForced air cooling, adjustable air speed

Product Maintenance:

No.ProtectionsRemarks
1PV current/power limiting protectionWhen charging current or power of the PV array configured exceeds the PV rated, it will charge at the rated.
2PV night reverse-current protectionAt night, the battery is prevented from discharging through the PV module because the battery voltage is greater than the voltage of PV module.
3Mains input over voltage protectionWhen the mains voltage exceeds 280V (230V model) or 140V (120V model), the mains charging will be stopped and switched to the inverter mode.
4Mains input under
voltage protection
When the mains voltage is lower than 170V (230V model /UPS mode) or 90V (120V model or APL mode), the mains charging will be stopped and switched to the inverter mode.
5Battery over voltage protectionWhen the battery voltage reaches the overvoltage disconnection point, the PV and the mains will be automatically stopped to charge the battery to prevent the battery from being overcharged and damaged.
6Battery low voltage protectionWhen the battery voltage reaches the low voltage disconnection point, the battery discharging will be automatically stopped to prevent the battery from being over-discharged and damaged.
7Load output short circuit protectionWhen a short-circuit fault occurs at the load output terminal, the AC output is immediately turned off and turned on again after 1 second.
8Heat sink over temperature protectionWhen the internal temperature is too high, the all-in-one machine will stop charging and discharging; when the temperature returns to normal, charging and discharging will resume.
9Overload protectionOutput again 3 minutes after an overload protection, and turn the output off after 5 consecutive times of overload protection until the machine is re-powered. For the specific overload level and duration, refer to the technical parameters table in the manual.
10PV reverse polarity protectionWhen the PV polarity is reversed, the machine will not be damaged.
11AC reverse protectionPrevent battery inverter AC current from being reversely input to Bypass.
12Bypass over current protectionBuilt-in AC input overcurrent protection circuit breaker.
13Battery input over current protectionWhen the discharge output current of the battery is greater than the maximum value and lasts for 1 minute, the AC input would switched to load.
14Battery input protectionWhen the battery is reversely connected or the inverter is short-circuited, the battery input fuse in the inverter will blow out to prevent the battery from being damaged or causing a fire.
15Charge short protectionWhen the external battery port is short-circuited in the PV or AC charging state, the inverter will protect and stop the output current.

Fault Handling:

No.FaultsHandling measures
1No display on the screenCheck if the battery air switch or the PV air switch has been closed;
if the switch is in the "ON" state; press any button on the screen to exit the screen sleep mode.
2Battery overvoltage protectionMeasure if the battery voltage exceeds rated, and turn off the PV array air switch and Mains air switch.
3Battery undervoltage protectionCharge the battery until it returns to the low voltage disconnection recovery voltage.
4Fan failureCheck if the fan is not turning or blocked by foreign object.
5Heat sink over temperature protectionWhen the temperature of the device is cooled below the recovery temperature, normal charge and discharge control is resumed.
6Bypass overload protection, inverter overload protection① Reduce the use of power equipment;
② Restart the unit to resume load output.
7Inverter short circuit protection① Check the load connection carefully and clear the short-circuit fault points;
② Re-power up to resume load output.
8PV overvoltageUse a multimeter to check if the PV input voltage exceeds the maximum allowable input voltage rated.
9Battery missed alarmCheck if the battery is not connected or if the battery circuit breaker is not closed.
China RS485 50/60Hz PV Hybrid Solar Inverter DSP Grid With Lithium Battery supplier

RS485 50/60Hz PV Hybrid Solar Inverter DSP Grid With Lithium Battery

Inquiry Cart 0