1K-5KVA Double Conversion Ups With Lithium Battery 127Vac

Brand Name:CONSNANT
Certification:ICE, ISO,CE
Model Number:CNS 3C-LV
Minimum Order Quantity:20 pieces
Delivery Time:5-7 days for sample order, 7-15 days for mass production
Payment Terms:T/T, L/C,
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Building B6, Junfeng Industrial Park, Fuyong Town, Bao'an District, Shenzhen City, 518103 P.R.China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

C1-5kVA LV(110V)ONLINE UPS Datasheet

Feature:


Zero Transfer time


True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues.


DSP Digital Control Based


Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply


Ultra Wide Input Mains range


Strong compatible with ultra with electric environment, stay well with ultra wide range mains of 60V~145V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life


Best Loading Capability


Up to 0.9 Output Power Factor , 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application


Genset Compatible


Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment.


High Input power factor


Thanks to digital controlled PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer


Reliable design


Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion.


Open to customization


Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system


Specification:


ModelC1K-LVC1KS-LVC2K-LVC2KS-LVC3K-LVC3KS-LVC5K-LVC5KS-LV
CapacityVA/W1kVA/800W2kVA/1.6kW3kVA/2.4kW5kVA/5.4kW
TopologyDouble Conversion Online UPS
PhaseSingle Phase Input Single Phase Output

AC

Mains Input

Wiring1 phase 3wires ( L / N+PE)
Rated Voltage110/115/120/127Vac
Voltage RangeLine-Neutral: 55~145VAC
Frequency Range40Hz-70Hz
Input Power Factor≥0.99
AC OutputWiring1 phase L/N+PE
Output Voltage110/115/120/127VAC
Voltage Regulation±2%
Output Frequency50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
WaveformPure Sine Wave

Distortion

(THDV%)

<2%(Linear Load)
<7%(None-Linear Load)
Over load capability

1Min@105%~125%Rated Load

30Sec.@125%~150%Rated Load

0.5Sec.@>150%Rated Load

10min@105%~125%

60s@125%~150%

0.5S@>150%

EfficiencyAC/AC Mode88%89%90%92%
DC/AC Mode85%86%87%90%

Battery

&

Charger

Rated Battery Voltage

24VDC

Internal

36VDC

External

48VDC

Internal

72VDC

External

72VDC

Internal

96VDC

External

144VDC

Internal

192VDC

External

Battery Capacity

12V/7AH

x2pcs

External Battery Depends

12V/7AH

X4pcs

External Battery Depends

12V/7AH

X6pcs

External Battery Depends

12V/7AH

X12pcs

External Battery Depends
Backup Time>6mins @ Half Load>6mins @ Half Load>6mins @ Half Load>6mins @ Half Load
Charging Current

standard Model with Internal Battery:1A

Long Backup Time Model :4A

PhysicalChassis StyleRACK / Tower (separated)

Tower Dimension

W x H x D (mm)

1KS: 145 x 220 x 250

1K, 2KS: 145 x 220 x 318

2K:145 x 220 x 390

3K/3KS: 190 x 318 x 368

C5KS-LV

190 x 360x 528

Rack Dimension

3KR/5KRS: 438mm(W) x 88mm(2U)(H) x 500mm(D) Include Internal Battery

1KR/1KSR/2KR/2KSR/3KSR: 438mm(W) x 88mm(2U)(H) x 360mm(D)

Weight (kg)8.94.2145.921.68.33716
HMILCD DISPLAYInput Mains Voltage, Frequency, Load level, Operation Mode, Health Status

Standards

COMMUNICATION

1. RS232 PORT

2. NMC Card: Support remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown

Optional Extension Card

CMC MODBUS Card, USB Card, Relay Card

(Needs assembly according to order request before shipping)

Operating Environment

Endurance

Temperature range-10~50oC
Relative Humidity0-98%(Non-condensing)
Acoustics Noise<55dB @ 1 meters

UPS Outlook


Front View

C1K(S)/2K(S) Bezel with 2 Button C3K(S)/5K(S) Bezel with 2 Button

C1K(S)/2K(S) Bezel with 4 Button C3K(S)/5K(S) Bezel with 4 Button



C1KR(S) 1U Rack UPS



C1KR(S)~C10KR(S) 2U Rack UPS


Rear Panel


C1K(S)/2K(S)-LV Rear Panel C3K(S) -LV Rear Panel



C5K (S)-LV Rear



C1KR 1U RACK UPS Rear Panel



C1KRS 1U RACK UPS Rear Panel


C1/2KR(S) 2U RACK UPS Rear Panel


C3KR(S)2U RACK UPS Rear Panel


NOTE:

① Battery Capacity and voltage is open to customization

② Dimension might vary for different bezel

③ The socket and terminal configuration on the rear panel may be different for countries or regions according to order

④ More parameter customization,please contact sales representative


Packing


Certification

China 1K-5KVA Double Conversion Ups With Lithium Battery 127Vac supplier

1K-5KVA Double Conversion Ups With Lithium Battery 127Vac

Inquiry Cart 0