450GPM@200PSI Ul Listed Fire Pumps One Stage 99.8KW Max Shaft Power

Brand Name:CNP NM FIRE
Certification:NFPA20/UL/FM/EN12845/CCCF
Model Number:PA65/32H (2.5"x2")
Minimum Order Quantity:1set
Delivery Time:30-45 Working Days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan Hubei China
Address: Rm. E, 16th FL., Century Bldg. No. 206, Jianghan Rd., Hankou, Wuhan, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Firefighting Pumps On 450GPM @ 200PSI Centrifugal End Suction Fire Pumps By UL Listed


Design Features according to UL / FM :
All interior bolt or screw that are exposed to pumped liquid shall be of rolled bronze or corrosion resistant material.
The pump shall be provided with automatic air-release valve, circulation relief valve and pressure gauges.
Bearings shall have an L-10 rating of not less than 5000 hours at maximum load.
The pumps shall be provided with at least four packing rings plus a lantern ring. The lantern ring may be permitted to replace one ring of packing.
Impellers, wear rings, shafts, lantern rings, glands shall be made of corrosion resistant material.


Parameters:


HEADPUMP MODELSPEEDMAX SHAFT POWER
PSIFEETMETERRPMHPKW
200461141PA65/32H
(2.5"x2")
2980
(50Hz)
13499.8

NFPA20, UL, FM, EN12845,CCCF


How it Works:


These types of pumps are usually powered by an A.C. electric motor, although some are D.C. motor driven, as well as air driven motors, hydraulic motors, gasoline and diesel engine driven and steam turbine driven. These pumps may be close-coupled, with the impeller directly attached to the driver shaft without a separate coupling between them. Alternatively, they may be mounted on a frame, where the pump has its own bearings and a coupling that separates the motor and the pump.


Performance Ranges:



UL:


Q: 100-750GPMH:100-145PSI

FM:


Q: 100-750GPMH:100-145PSI

CCCF:


Q:5-150L/SH:0.40-1.6Mpa

NFPA20:


Q: 100-2250GPMH:60-230PSI

Product Type:


End Suction Fire Pump


NFPA20 Package


Advantage:


First-Class testing and inspection equipment.

UL certification represents the world's highest technical standards of fire certification,but also means that certified fire products must withstand the most extreme,harsh test process,the purpose of certification designed to verify whether the product meets the performance,safety and quality requirements,so as to achieve the purpose of property protection.

China 450GPM@200PSI Ul Listed Fire Pumps One Stage 99.8KW Max Shaft Power supplier

450GPM@200PSI Ul Listed Fire Pumps One Stage 99.8KW Max Shaft Power

Inquiry Cart 0