Add to Cart
Dysphagia physiotherapy cable for NMES devices swallowing therapy cable
Product Description
An adjunctive modality that unites the power of electrical
stimulation with the benefits of swallowing exercise. VitalStim
Therapy is a non-invasive, external electrical stimulation therapy
that re-educates the throat muscles needed for swallowing. The
device is a portable, dual-channel electrotherapy system that is
used with electrodes specifically designed for application to the
muscles of the throat.
The VitalStim electrode has a unique construction to safely
transmit the high current load and current density of the VitalStim
Therapy protocol. Unique design and material stretches and molds to
the irregular surface of the anterior neck. Material tears without
scissors for quick application. Constructed to provide reliable
conductivity with no internal electrode separation. Excellent
adhesion and gentle removal for delicate skin
the electrode cable is Compatible Throat therapeutic instrument Vitalstim5900, also supply this cable with snap button end.
Shipping choices:
DHL | About 3-5 working days Good at Asia,America,Europe,etc |
FedEx | About 3-7 working days Good at India,America,Europe,etc |
UPS | About 3-6 working days Good at America,Europe,South Africa,etc |
TNT | About 3-8 working days Good at The middle east,Africa |
EMS | About 15-20days Good at The Russian Federation |
SF express | About 5-10 working days Good at America,Asia,etc |
By Air | About 4-7 working days Most country available |
By Sea | About 7-30 days Only available for coastal areas.Cheapest and longest |
1. In-Warranty Period: we will give the replacement for all quality problems in time under normal conditions of use.
2. If the new items can not work with your devices, we will send
new replacement or refund in time.
Features
· Two independant channel stimulation providing the ability to
apply 4 electrodes
· Large digital display for better treatment control
· 0,5 mA step for amplitude settings allows for a very precise
stimulation level
· Constant current generator for better comfort
Specification
· Waveform: Biphasic pulsed with interphase interval (VMS)
· Frequency: 80 Hz
· Phase duration: 300 microseconds
· Duty cycle: 57 seconds ON, 1 second RAMP DOWN, 1 second OFF, 1
second RAMP UP
· Treatment duration: 60 minutes (per patient tolerance)
· Intensity: Increase to a submaximal motor recruitments level, not
to exceed 25 milliamperes
· Electrode placements: One of several possible combinations on the
anterior neck and face based on the muscle groups that are targeted