OOM102 Envitec Medical Oxygen Sensor White Compatible With MOX-01 O2 Cell Sensor

Brand Name:envitec
Certification:CE,ISO
Model Number:OOM102
Minimum Order Quantity:1pcs
Delivery Time:2-3 work days
Payment Terms:T/T, Western Union,
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 4th-5th Floor,Building 3,19th North Danzi Road,Kengzi Street,Pingshan Dist,Shenzhen,China
Supplier`s last login times: within 22 hours
Product Details Company Profile
Product Details

OOM102 envitec medical oxygen sensor compatible with MOX-01 O2 cell sensor


Product Description

Product ModelOOM102
Measurement range0-100% oxygen
Output in ambient air9 to 14mV
Electrical interface

OOM102: 3pin(Molex 22-11-1031)

OOM102-1:3,5mm Mono Jack

Accuracy and repeatability<1% volume O2 when calibration in 100% oxygen
Linearity error<3% relative
Response time<12 seconds, to 90% of final value
Zero Offset Voltage<200uV in 100% nitrogen applied after 5 minutes
Cross Interference

<0.5% Vol.O2 response to:

10% CO2 balanced N2

80% N2O balanced N2

7.5% halothane in balanced N2

7.5% isoflurane in balanced N2

7.5% enflurane in balanced N2

9% Sevoflurane in balanced N2

20% desflurane in balanced N2

Influence of Humidity-0.03% relative per% RH at 25 ℃
Influence of PressureProportional to change in oxygen partial pressure
Influence of mechanical shock<1% relative after a fall from 1 meter
Operating temperature0 ℃ -50 ℃
Temperature compensationBuilt-in NTC compensation
Effect of Temperaturebetween +25 ℃ and +40 ℃, 3% relative error
Compensation (steady state)between 0 ° C and +50 ° C, 8% relative error
Working humidity0-99% RH non-condensing
Longoing Term Output Drift<1%vol oxygen per month typically <-15% relative over lifetime
Storage temperature-20 ℃ to +50 ℃
Recommended storage temperature+5 ℃ +15 ℃
Recommended load≥10Ω
Warm-up time<30 minutes, after replacement of sensor
Rated sensor life≥1 000 000% volume oxygen hours
Weightapproximately 28 grams

Use the advantages:

Meet EN ISO 21647

• Designed and manufactured according to EN ISO 9001 : 2000 and EN ISO 13485 : 2003
• Accurate and reliable response

• Resistant to N2O

• Excellent signal stability

• High product quality
• Short lead times

After-sale services

1. In-Warranty Period: we will give the replacement for all quality problems in time under normal conditions of use.

2. If the new items can not work with your devices, we will send new replacement or refund in time.

China OOM102 Envitec Medical Oxygen Sensor White Compatible With MOX-01 O2 Cell Sensor supplier

OOM102 Envitec Medical Oxygen Sensor White Compatible With MOX-01 O2 Cell Sensor

Inquiry Cart 0