Home /Financial Equipment /

Plastic Bottle Wall Thickness Gauge , 8600 Container Material Thickness Testing Machine

Plastic Bottle Wall Thickness Gauge , 8600 Container Material Thickness Testing Machine

Brand Name:POOTAB
Certification:SGS,CE,ISO
Model Number:Magna-Mike 8600
Minimum Order Quantity:1 Sets
Delivery Time:About 15 Working Days After Order
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: 150 Fenxi Road, Shangjia Urban Industrial Park, Building 2, Wanjiang District, Dongguan City, Guangdong Province
Supplier`s last login times: within 29 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Plastic Bottle Wall Thickness Gauge 8600 Container Material Thickness Testing Machine

Application :

Olympus Magna-Mike8600 wall thickness gauge is a portable thickness gauge, which uses simple magnetic method to measure the thickness of non-ferrous materials reliably and with strong repeatability. Magna-Mike instrument is easy to operate. When measuring, press or move the magnetic probe on one side of the material to be measured, and put a small target steel ball (or target disc or target steel wire) on the other side of the material or in a container. The Hall effect sensor of the probe measures the distance from the probe end to the target steel ball. The measured distance is displayed on the screen as a digital form of thickness reading for easy reading.


New Features :

1. Three new durable probe designs:

--Straight, Right Angle, and Low-profile Articulating

2. Replaceable Wear Caps

--Standard, Chisel tip, and Extended Wear (for 86PR-1 and 86PR-2 only)

3. Expanded target selection

--3/16 and 1/4 in. magnetic target balls

--0.045 in. (1.14 mm) 0.026 in. (0.66 mm) diameter wire target

4. Expanded thickness range up to 25.4 mm (1.00 in.)

5. Larger Color VGA display

6. RS-232, USB and VGA outputs

7. Fast Measurement update rate 60 Hz

8. Expanded alphanumeric data logger

9. Save and Recall stored calibration files

10. Ability to export file to MicroSD card in .txt and CSV formats

11. New accessory kits (Calibration kits)

--Standard up to 9.1 mm (0.360 in.)

-Extended range up to 25.4 mm (1 in.)

--Disk kit

--Wire target kit

--Low-profile probe kit


Three New Probe Designs :

The Magna-Mike is available with straight, right angle, and low-profile articulating magnetic probes.The 86PR-1 and 86PR-2 feature replacable wear cap to extend the probe's durability and reduce replacement costs.

Measures from 0.001 mm (0.0001 in.) to 25.4mm (1 in.)

TargetsMin ThicknessMax ThicknessAccuracy
Basic CalibrationMultipoint
86PR-1 and 86PR-2
1/16 in. (1.58 mm) ball (80TB1)0.0001 in. (0.001 mm)0.080 in. (2.03 mm)4%3%
1/8 in. (3.17 mm) ball (80TB2)0.0001 in. (0.001 mm)0.240 in. (6.1 mm)4%2%
3/16 in. (4.76 mm) ball (80TB3)0.0001 in. (0.001 mm)0.360 in. (9.1 mm)3%1%
1/4 in. (6.35 mm) ball (80TB4)0.0001 in. (0.001 mm)0.360 in. (9.1 mm)3%1%
3/16 in. (4.76 mm) magnetic ball (86TBM3)0.160 in. (4.06 mm)0.750 in. (19.05 mm)3%1%
1/4 in. (6.35 mm) magnetic ball (86TBM4)0.160 in. (4.06 mm)1.00 in. (25.4 mm)3%1%
0.500 in. (12.7 mm) flat disk (80TD1)0.0001 in. (0.001 mm)0.360 in. (9.1 mm)3%2%
0.250 in. (6.35 mm) V-edge disk (80TD2)0.0001 in. (0.001 mm)0.240 in. (6.0 mm)3%2%
0.045 in. (1.14 mm) dia. wire (86TW1)0.0001 in. (0.001 mm)0.500 in. (12.7 mm)3%2%
0.026 in. (0.66 mm) dia. wire (86TW2)0.0001 in. (0.001 mm)0.240 in. (6.1 mm)
New 86PR-3 Low-profile Articulating Probe
1/16 in. (1.58 mm) ball (80TB1)0.0001 in. (0.001 mm)0.080 in. (2.0 mm)4%3%
1/8 in. (3.17 mm) ball (80TB2)0.0001 in. (0.001 mm)0.160 in. (4.1 mm)4%2%
0.026 in. (0.66 mm) dia. wire (86TW2)0.0001 in. (0.001 mm)0.160 in. (4.1 mm)3%2%

The Magna-Mike offers an expanded list of target options greatly extend its measurement capability.

Note: For 86PR-1 and 86PR-2 probes the Measurement Tolerance = [(accuracy x thickness) +0.0001 in. or 0.0003 mm)], for 86PR-3 the Measurement Tolerance = [(accuracy x thickness) + (0.001 in. or 0.0025 mm)]


Internal Alphanumeric Data Logger

The Magna-Mike® has an extensive file-based alphanumeric data logger that is designed to easily store and transfer thickness readings.

You have the ability to store thickness readings in one of four standard file formats: Incremental, Sequential, Sequential with Custom Point and 2-D Grid.

  1. Single Send or File Send directly to an Excel spread sheet using WINXL
  2. Send data to other SPC program
  3. Both USB and RS-232 outputs
  4. Export files to a removable MicroSD card in .txt and CSV formats
  5. Generate on-board reports

Direct Interface to Excel Spread Sheets

The Magna-Mike 8600 has RS-232 and USB outputs that enable the instrument to directly send data to an Excel spread sheet. The included WINXL interface program enables you to single send or file send thickness readings.

Specifications :


GeneralOverall dimension236 mm x 167 mm x 70 mm
(9.3 in. x 6.57 in. x 2.76 in.)
Weight1.68 kg (3.72 lb), including lithium-ion battery
KeypadEnglish, Japanese, Chinese, International
LanguagesEnglish, Spanish, French, German, Japanese, Chinese, Portuguese, Swedish, Norwegian, Dutch, Polish, Russian, Hungarian, Czech, Italian
Data storageOnboard and removable 2 GB MicroSD card
Battery life (Optional)16 h (lithium-ion)
Power requirementsAC Mains: 100 VAC to120 VAC, 200 VAC to 240 VAC
Display typeFull VGA (640 x 480 pixels) transflective color LCD
Display dimensions (W x H, Diag.)117 mm x 89 mm, 146 mm
(4.62 in. x 3.49 in., 5.76 in.)
Min/Max capture modeCaptured at 60 Hz measurement rate
Display update rate4, 8, 16 and 20 Hz
AlarmHigh and Low alarms
Resolution0.1 mm (0.01 in.), 0.01 mm (0.001 in.), 0.001 mm (0.0001 in.) (depending on thickness range)
Data loggerInternal file-based alphanumeric data logger
Probes86PR-1Standard straight probe 82.30 mm (3.24 in) long and 18.62 mm (0.733 in.) dia.
86PR-2Right angle probe head 58.84 mm x 18.62 mm, length 178.57 mm (2.32 in. x 0.733 in. dia.,length 7.030 in.)
86PR-3Low-profile articulating probe 241.3 mm (9.5 in.) long
Environmental TestingVibrationMIL-STD-810G, Method 514.6, Procedure I
DropMIL-STD-810G, Method 516.6, Procedure IV
ShockMIL-STD-810G, Method 516.6
Designed for IP67Yes
Inputs/OutputsUSBUSB 2.0 peripheral port
RS-232Yes
Memory cardMaximum capacity: 2 GB removable MicroSD memory card
Video outputVGA output standard
Foot switch (optional)Programmable (Save, Send, Meas or Q-Cal)
Operation temperature-10 °C to 50 °C (14 °F to 122 °F)

Standard Inclusions :

Select probe and stand (straight, right angle, or low-profile):

  • 86PR-1 (U8470020): Standard probe includes
  • 86PRS1 (U8771043): Two part probe stand
  • 86PR-2 (U8470028): Right angle probe includes
  • 86PRS (U8771044): Two-part right angle probe stand
  • 86PR-3s (Q7800004): Low-profile probe includes
  • 86PRS3 (Q7800006) and tow part low-profile probe stand
  • 86PC (U8801410): Probe cable for 86PR-1 and 86PR-2
  • WinXL (U8774010): Interface program to Excel

Select one from:

86ACC-KIT (U8771068): Standard calibration kit,

86ACC-ER-KIT (U8771069) Extended range calibration kit or

86ACC-PR3-KIT (Q7800005) Low-profile calibration kit.

EP-MCA: External power supply with charger

8600-MAN-CD (U8778535): CD with manual (all languages)

600-TC (U8780294): Plastic carry case

Select one from:

600-C-RS232-5 (U8780299): RS-232 cable

EPLTC-C-USB-A-6 (U8840031): USB cable

Standard inclusions may vary depending on your location. Contact your local distributor.


Standard inclusions may vary depending on your location.


Optional Accessories :

l 86PR-3 (Q7800004): Low-profile articulting probe

l 600-C-VGA-5 (U8780298): VGA output cable

l 600-BAT-L-3 (U8051431): Rechargeable lithium-ion battery

l 85FSW (U8780127): Remote footswitch

l 86PR-2 (U8470028): Right angle probe

l 86PRS2 (U8771044): Two-part probe stand for 86PR-2

l 86PCC (U8780323): Coiled cable for 86PR-1 and 86PR-2

l 86PR1-WC (U8780324): Replaceable wear cap for 86PR-1 and 86PR-2 probes

l 86PR1-CWC (U8780326): Chisel tip wear cap for 86PR-1 and 86PR-2 probes

l 86PR1-EWC (U8780344): Extended wear cap for 86PR-1 and 86PR-2 probes

l 80TB1 (U8771030): Target balls 1.58 mm (1/16 in.)

l 80TB2 (U8771031): Target balls 3.17 mm (1/8 in.)

l 80TB3 (U8771032): Target balls 4.76 mm (3/16 in.)

l 80TB4 (U8771022): Target balls 6.35 mm (1/4 in.)

l 80TD1 (U8771034): Target disk Flat edge

l 80TD2 (U8771035): Target disk V-edge

l 86TBM3 (U8771039): Magnetic target balls 4.76 mm (3/16 in.)

l 86TBM4 (U8771040): Magnetic target balls 6.35 mm (1/4 in.)

l 86TW1 (U8771041): Wire target 1.14 mm (0.045 in.)

l 86ACC-ER-KIT (U8771069): Extended calibration kit

l 86ACC-W-KIT (U8771070): Wire target calibration kit

l 86ACC-D-KIT (U8771071): Target disk calibration kit

l 86ACC-PR3-KIT (Q7800005): Low-profile probe calibration kit

l 80CAL-NIS (U8771011): NIST-traced calibration standards (set of six)


Magna-Mike8600 Wall Thickness Gauge Picture :


China Plastic Bottle Wall Thickness Gauge , 8600 Container Material Thickness Testing Machine supplier

Plastic Bottle Wall Thickness Gauge , 8600 Container Material Thickness Testing Machine

Inquiry Cart 0