Walk In Temperature Humidity Test Chamber , Inner Volume 8 Cubic Constant Temerature Room

Brand Name:POOTAB & PERFECT
Certification:ISO, SGS, CE
Model Number:PT-2100-8000
Minimum Order Quantity:1 Set
Delivery Time:30 Working Days
Payment Terms:T/T, Western Union, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: 150 Fenxi Road, Shangjia Urban Industrial Park, Building 2, Wanjiang District, Dongguan City, Guangdong Province
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

Walk In Chamber Temperature Humidity Test Room , Inner Volume 8 Cubic Constant Temerature Room


Application: Constant temperature and humidity room is suitable for low temperature, high temperature, high temperature variation, constant time heat, high and low temperature alternating humidity and heat test of the whole machine or large parts.The size and function of the studio can be changed according to the user's requirements.Block box body, beautiful and generous shape;Scientific duct design, can meet the needs of different customers;Adopt touch screen, PLC program controller.


Meet Standards :

GB/T2423.3-93(IEC68-2-3) Test Ca

GJB150.3-2009

GJB150.4-2009

GJB150.9-2009

GB2423.1-2008

IEC6008-2-1-2007

GB/T 2423.2-2008

GB/T5170.18-2005

GB/T10586-2006

GB/T 10589-2008


Specifications:

  • Model
PT-2100-8000 Walk-in programmable temperature humidity room
1.1 Innner Size2000*2000*2000 mm (W*D*H)
1.2 Outer SizeAbout 2300*4200*2380 mm (W*D*H), refer to designed size
1.3 WeightAbout 2800kg
  • Performance

( refer to condition of the water-cooled water temperature of 25℃, without specimen)


2.1 Environmental conditions

Temperature 5-35℃,relative humidity≤90%(when 25℃)


2.2 Power Supply

AC 380V,50Hz,3 phase 4W+ground wire

(grounding resistance < 4 Ω)

2.3 Temperature Range-60℃→+120℃
2.4 Temperature Resolution0.01℃
2.5 Temperature Fluctuation≤±0.5℃
2.6 Temperature Deviation≤±2℃
2.7 Temperature Uniformity≤±2℃
2.8 Heating Rate

≥ 2℃/ min, nonlinear (no load)

+20℃→+120℃ ≤50 min (no load)

2.9 Cooling Rate

≥ 2℃/ min, nonlinear (no load)

+20℃→-60℃ ≤40 min (no load)

2.10 Humidity Resolution0.1%R.H
2.11 Humidity Range10%~98%R.H

2.12 Humidity Fluctuation


±2.5%R.H.

2.13 Humidity Deviation

When >75%RH:≤±2,3%RH,

When<75%RH:≤±5%RH


Walk in Chamber Picture :

China Walk In Temperature Humidity Test Chamber , Inner Volume 8 Cubic Constant Temerature Room supplier

Walk In Temperature Humidity Test Chamber , Inner Volume 8 Cubic Constant Temerature Room

Inquiry Cart 0