36kV Compact Transformer Substation For Photovoltaic Power Generation

Brand Name:TIANAN
Certification:ISO9001-2000, ISO9001, CCC
Model Number:ZGS-Z. G-/35
Minimum Order Quantity:1unit
Delivery Time:45 work days
Payment Terms:L/C, T/T, D/P, D/A
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang China
Address: 3/F, Building B7 , 999 Yangfan Road,High-tech Zone, Ningbo, China 315040
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

36kV Combined Transformer for Photovoltaic power generation

Product Description:

Summarize:
ZGS-Z.F-/36 series wind power combined transformer is a special power equipment integrating step-up transformer, HV current limited fuse, load switch, LV switch and related auxiliary equipments. It transforms the 0.69kV voltage produced by wind power motor into 35kV,and output the electricity through 35KV cable circuit, which is the ideal equipment in wind power complete set equipment.

Normal ambient conditions for service:
1. Altitude shall be within 2000m
2. Ambient temperature range shall be : -40ºC~+40ºC
3. Outdoor wind speed shall not exceeds 35m/s
4. Relative humidity: daily average value shall not exceed 95%, monthly average value 90%
5. Installation site: indoor
6. Service environment: installed in sites with no fire or explosion danger, serious fifth, chemical corrosion and fierce vibration.
7. When transcend the above normal ambient conditions for service, users can negotiate with us to solve.


Product technical parameter
Parameter of 35kV oil immersed load switch
Table 1
S/NNameUnitParameter
1Rated voltageKV40.5
2Rated currentA315630
3Rated frequencyHz50
4Rated short-circuit withstand currentkA/2s12.520
5Rated peak withstand currentkA31.550
6Mechanical endurancetimes>2000
71 min power withstand voltage (phase-to-phase, phase-to-earth)kV95
8Lightning impulse level (phase-to-phase, phase-to-earth)KV185

Parameter of 35kV fuse
Table 2
Rated voltageFuse rated current AFusing element rated current ARated Max. breaking current kA
40.54020,25,31.5,40,50,6331.5

Parameter of lightning arrester
Table 3
Rated voltageContinuous operating voltageDC reference voltage (1mA)Nominal discharging currentNominal discharging current residual2ms square-wave current withstand value

51kV
40.8kV≥73kV5kA(peak value)≤134kV (peak value)≥250A(peak value)

Condensation controller and other auxiliary equipment can be added in the body as per clients' requests.
Note: As per different requirement from client, the capacity of transformer can be customized.
China 36kV Compact Transformer Substation For Photovoltaic Power Generation supplier