AC Series - High Voltage Two Terminal AC Line Protector High Surge Voltage Protection


AC series two-electrode line protectors provide a high degree of surge protection in AC line applications. The two models, AC120 and AC240 are designed for use with 120VAC and 240VAC lines respectively. They are able to extinguish AC follow-on currents of at least 200A.


CG3 two electrode high voltage (1.0 - 7.5 KV) devices are designed for surge protection and high isolation applications, and for applications for which bias voltages or signal levels of several hundred volts are normally present.


Features

• Rugged ceramic-metal construction

• Low capacitance (<1.5 pF)

• Available in tape-andreel packaging

• Available with or without leads


Applications


AC Series:

• Long branch circuits (AC wall outlet)

• Short branch circuits (at breaker box, computer, etc)

• Power supplies • Test equipment

• Submersible pumps

• Medical electronics


CG3 Series:

• CRT terminals

• CATV equipment

• Antennas

• Power supplies

• Medical electronics


Electrical Specifications

Part NumberDevice Dimension
Type
Device Specifications (at 25°C)Life Ratings
DC Breakdown
in Volts
(@100V/s)
Impulse
Breakdown

in Volts
(@100V/µs)
Impulse
Breakdown
In
Volts
(@1 Kv/µsec
Insulation
Resistance
Capacitance

(@1MHz)
Arc
Voltage
(on state
Voltage)
@1Amp Min
Follow
On
Current3
Nominal
AC
Discharge
Current
(10x1sec
@50-60Hz)
AC
Discharge
Current
(1 x 50Hz
9 cycles)
Nominal
Impulse
Discharge
Current4
(@8/20µs)
Max
Surge
Current5
(@8/20µs)
MINTYPMAXMAX/MINMAXTYP/////
AC1201A23028534050055010 GΩ (at 100V)<1.5 pf~ 25 V200 Amps5 A65 A10 shots 5kA1 shot 10kA
AC2401A48060072011001200
CG3 1.01A800100012001400150010 GΩ (at 100V)<1.5 pf~ 25 V200 AmpsN/AN/A10 shots 5kA1 shot 10kA
CG3 1.11A8801100132016001700
CG3 1.21A9601200144017001800
CG3 1.31A10401300156018001900
CG3 1.51A12001500180018002000
CG3 2.01A16002000240025002750
CG3 2.51A20002500300032003500
CG3 2.71A21602700324036004000
CG3 3.01A24003000360040004200
CG3 3.31A26403300396046004700
CG3 4.02B32004000480058006000
CG3 4.52B36004500540061506500
CG3 5.02B40005000600075008000
CG3 6.22.7B49606200744081009500
CG3 6.52.7B520065007800950010000
CG3 7.52.6.7B6000750090001000010600

1. Refer to Production Dimensions section, outline A devices

2. Refer to Production Dimensions section, outline B devices

3. Tested to UL1449 -- 120V r.ms. for AC120, 230V r.m.s. all others. Conducted with suitable MOV connected in series.

4. 10 x [5(+) and 5(-)] applications 5kA @ 8/20µs

5. 1 x [1(+) and 1(-)] application 10kA @ 8/20µs

6. CG3 7.5 product UL approval is currently pending

7. When ordering this item, use suffix code D004 when entering the part number. The older product version without D004 suffix code has been discontinued. Refer to Part Numbering System section for additional information.


Dimension unit


FAQ


1. What is your MOQ?
A: We provide you small MOQ for each item, it depends your specific order.
2. What is your delivery date?
A: The delivery date is about 2-7days after receipt of payment.
3. What is your payment terms?
A: We accept T/T, western union, ,70% deposit in advance and 30% balance before shipment.
4. Can you send free samples?
A: Yes, free samples are available; you just need to pay the express fee. You can provide your a/c like DHL, or you can call your courier to pick up from our office.
5. How do you carry out quality control?
A: Quality is our priority. Our QC always attach great importance to quality control from the very beginning to the end.
6. Can you accept OEM orders?
A: Yes, we accept OEM & ODM orders, welcome all types of customized orders and cooperation.


Please tell me:
What product specifications do you need? when you ask for a quotation.I will give you the most competitive price per as your requirements. And we have many types for you to choose.


P.S.:If you can't find any products to meet your requirements. welcome to send us the details drawings so that we can provide us our professional & best service to you.

China High Voltage Two Terminal AC Line Protector High Surge Voltage Protection supplier

High Voltage Two Terminal AC Line Protector High Surge Voltage Protection

Inquiry Cart 0