Compact Zero Sequence Current Transformer Ring Net Cabinet 5P10 Ratio 100A / 1A

Brand Name:GFUVE
Certification:IEC60044-1, ISO9001,GB,CNAS, CE
Model Number:LZCG530-10-100
Minimum Order Quantity:3 Pieces
Delivery Time:3-7 Days
Payment Terms:T/T, Western Union,Paypal, L/C, D/A, D/P
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

LZCG530-10 Zero Phase Current Transformer, Ring net cabinet 5P10 Ratio 100A / 1A Zero Sequence Current Transformer


100A Zero Phase Current Transformer The 200A zero phase current transformer can endure input current ranging from 50A to 100A. If the monitored circuit malfunctions, it can output zero phase current which is 500 times smaller than the input current with the suggested 500 turns ratio so that the power supply is cut off to protect the electric equipment.


The unbalanced current flows in the circuit during the earth fault is known as the zero sequence current or the DC component of the fault current.The zero phase sequence means the magnitude of three phases has zero phase displacement.The three vector lines represent the zero sequence current and it is detected by adding the vector of three phases current.


Zero phase current transformer which detects the difference between the currents flowing in a number of conductors. The current flowing to a load must equal the current flowing back from the load. If this is not the case, a potentially dangerous residual current will be flowing somewhere in the installation.

LZCG530-10 Straight-Through zero sequence Current Transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in not only compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus, Unstitch, Schneider RM6, SM6, Siemens 8DJ10/8DH10, Simosec, FBX, Fluokit, Omar Garbo GA, GAE; SEL TPS(Q); VEI Unifluorc; Eaton SVS/12 ring network, but also cable distribution boxes because of its small size, light weight, operable and convenient installation. It is very convenient that the transformer can be directly installed at the inlet and outlet cables.

Definition: The unbalanced current flows in the circuit during the earth fault is known as the zero sequence current or the DC component of the fault current.The zero phase sequence means the magnitude of three phases has zero phase displacement.The three vector lines represent the zero sequence current and it is detected by adding the vector of three phases current.
Zero sequence current transformers, also known as core balance current transformers (CBCT), detect the presence of zero sequence currents during short circuit fault conditions such as the occurrence of a single line to ground fault that causes unbalanced currents in three-phase systems.
Zero sequence filtering is a concept used to eliminate zero sequence current component from the secondary current of Current Transformer used in Differential Protection of Transformer. This concept is useful in Transformer having earthed Star winding.


Zero-phase-sequence current transformer A current transformer has a primary winding, a core and asecondary winding, although some transformers, including current transformers, use an air core.



Parameters

Technical parameters 
StandardsIEC60044-1; IEC 61869-2; ANSI C57.13;NTC 2205; GB1208-2006
Rated primary current30-1000A
Rated load≤20VA
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current120%I1n
Secondary winding power-frequency voltage3kV, 1min
Instrument security factorFS ≤10
Mechanical parameters 
Dimensions (W×D×H) (mm)φ45xφ120x65
Weight (kg)2.1-10
Operating conditions 
Operating temperature-35°C to +55°C
Daily average temp<+40°C
Altitude<3500 meters
Operating conditions - continued 
ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.


Technical Data

TypeLZCG530-10LZCG530-10LZCG530-10
PurposeMeasuring current transformerProtection current transformerDouble winding current transformer
Rated primary current (AMP)Accuracy class and rated load(VA)Accuracy class and rated load(VA)Composite accuracy class and rated load(VA)
0.2S0.20.510P2010P1510P100.2S0.510P1510P10
30  2       
40  2.5       
50  3.75  2    
75 3.755 23.75    
1002.557.5 2.53.75    
15057.5102.53.756.252.53.75 2.5
2007.510153.7557.557.5 3.75
30010152057.5107.5102.55
4001520256.257.5151012.53.755
5002025256.257.51515153.755
6002030307.5102015203.757.5


Order information
If you have any demand for our products,please feel free to contact us.

China Compact Zero Sequence Current Transformer Ring Net Cabinet 5P10 Ratio 100A / 1A supplier

Compact Zero Sequence Current Transformer Ring Net Cabinet 5P10 Ratio 100A / 1A

Inquiry Cart 0