FU16 333mv Mini Dual Core Current Transformer Low Phase Shift For Power Measurement

Brand Name:GFUVE
Certification:CE, UL, ISO9001
Model Number:Fu-16
Minimum Order Quantity:3PCS
Delivery Time:3-7days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

FU16 economic 333mv mini split core current transformer for meter


Split core current transformers


Current transformer principle is based on the principle of electromagnetic induction. Current transformer is composed of closed core and winding. Its primary winding winding few, string in the need to measure the current line, it often has all the current flowing lines, the secondary winding more turns, in series with the measuring instruments and protection circuit, When the current transformer is working, its secondary side circuit is always closed, so the impedance of the measuring coil and the protective circuit in series is very small, and the working state of the current transformer is close to short circuit. Current transformer is the primary side of the current into a secondary side of the small current to use, the secondary side can not be open.


Applications


FU-16 series of split-core current transformer offers 333mV, 100mV-2V and 10mA-200mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect FU-16 series to meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
Features


The current transformer with high strength PVC shell, all cast bus structure. Transformer directly stuck in the cable Three rubber rings to resist the cable and cable with one. Transformer core using high-quality silicon steel roll, the second wire wound evenly on the core. Transformer open structure can not cut off the cable installation


Features

  • Most cost-effective
  • Faster installation
  • Safe and easy installations
  • High accuracy 0.5
  • Holding wire diameter: φ16mm
  • Measurement range of 1mA to 200A AC
  • Low phase shift for power measurement
  • Output model: Lead output(2.5m)
  • Isolated plastic case recognized according to UL94-V0
  • Small-size, compact size, light-weight
  • Over-Voltage protection circuit is installed.
  • CE, UL / EN 61010 - 1 certified


PARAMETERS


Technical parameters 
StandardsIEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
Ratio1000: 1 or 2000:1 , customized
Nominal input current(Primary current)20A/30A/40A/50A/60A/80A/100A/150A/200A
Overload withstand1.2 times rated current continuously
Accuracy0.2%, 0.5 %, 1%
System Voltage720V(0.72kV)
Output signal10mA-200mA AC optional
333mV AC or 100mV-2V optional
Frequency range40 Hz-500 Hz
Dielectric strength3KV 50Hz/60Hz at 1 minute
OutputStandard 2.5 meter cable
Protection Level3.0V0-P
Installation CategoryCATⅡ or CATⅢ 600VAC
Max. jaw opening16 mm
Mechanical parameters 
Dimensions (W×D×H) (mm)38mm×55mm×18mm
Weight(g)60
Operating conditions
Operating temperature-25°C to +55°C
Relative Humidity0-85% non-condensing
Altitude<3500 meters
ConditionNo existence of severely begrimed, erosive and
radioactive gas in the air. Permission of long-term
operation under rated current.