11KV Resin Cast Split Core Current Transformer , Low Voltage Current Transformer Outdoor

Brand Name:GFUVE
Certification:CE, UL, ISO9001
Model Number:LZCK322-10-2
Minimum Order Quantity:3 PCS
Delivery Time:3-7 days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

Resin 11KV Split Core Current Transformer Outdoor High Quality


Introduction


LZCK series split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.
It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes.
The transformer can be directly installed at the inlet and outlet cables. The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.



Features


The current transformer with high strength PVC shell, all cast bus structure. Transformer directly stuck in the cable Three rubber rings to resist the cable and cable with one. Transformer core using high-quality silicon steel roll, the second wire wound evenly on the core. Transformer open structure can not cut off the cable installation



PARAMETERS


Technical parameters 
StandardsIEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class0.5S, 0.5%, 1%, 3%
Range of primary rated current100-1500A
Range of Rated load≤10VA
Rated frequency50/60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current150%I1n
Secondary winding power frequency withstand voltage3kV, 1min
Safety Factor Rating(FS) <10
Output signal1A, 5A, 333mV, 1V or 5V(customized)
Cable length2.5m, 5m, 10m(customized)
Flame retardant ABS plastic shell inside, jaw waterproof apron.
Mechanical parameters 
Aperture (mm)Φ55
Dimensions (W×D×H) (mm)180×138×52
Weight (kg)2
Working conditions 
Operating temperature-35°C to +65°C, not exceeding +40°C
Storage temperature-40°C to +70°C
Ingress ProtectionIP65
Environmentoutdoors or indoors
The Height of above sea level0- 3000m
ConditionsNo existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.

SELECTION GUIDE


Technical parameters 
StandardsIEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current30-600A
Rated load≤10VA
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current120%I1n
Secondary winding power-frequency voltage3kV, 1min
Instrument security factorFS≤10
Mechanical parameters 
Dimensions (W×D×H) (mm)φ50xφ110x52
Weight (kg)1.6
Operating conditions 
Operating temperature-35°C to +55°C
Daily average temp<+40°C
Altitude<3500 meters
ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

TECHNICAL DATA


TypeLZCK322-10LZCK322-10
PurposeMeasuring current transformerProtection current transformer
RatioAccuracy class and rated load(VA)Accuracy class and rated load(VA)
I1/I20.51310P1510P1010P5
30/1 11.5   
50/1 12  1.25
75/1 1.52.5 12
100/122.53 1.52.5
200/12.5  1.252.5 
300/13.75  1.252.5 
400/17.5  1.252.5 
500/110  1.253 
600/110  1.53 
50/5  2.5   
75/5  2.5   
100/52.5     
200/53.75     
300/55     
400/57.5   2.5 
500/57.5   2.5 
600/510   3.75 

SELECTION GUIDE


ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proof
LZCK-55100-1500A≤10VAφ55180×138×522PCIP65
LMCK185-10300-3000A≤25VAφ185350×283×554.5PCIP65
LZCK310-10300-600A≤10VAφ50φ50 x φ110 x 321Resinsilicon case (option)
LZCK322-1030-600A≤10VAφ50φ50 x φ110 x 521.6Resinsilicon case (option)
LZCK350-1020-600A≤25VAφ50φ50 x φ110 x 1053.1Resinsilicon case (option)
LZCG530-1030-600A≤20VAφ45φ45 x φ120 x 652.1Resinsilicon case (option)

Wiring diagrams


P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
P2, S2 is homonymous terminals (subtractive polarity).


Product picture

China 11KV Resin Cast Split Core Current Transformer , Low Voltage Current Transformer Outdoor supplier

11KV Resin Cast Split Core Current Transformer , Low Voltage Current Transformer Outdoor