750 MA Bus Current Redundant Power Supply Module 140 CRP 932 00

Brand Name:Schneider
Model Number:140 CRP 932 00
Minimum Order Quantity:1
Delivery Time:2-3 work days
Payment Terms:T/T, Western Union
Place of Origin:FR
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

Redundant Power Supply Module SCHNEIDER TSX QUANTUM 140 CRP 932 00




General Specifications
Module Type 8 Channel IN Differential
External Power Not required
Bus Current required (Module) 240 mA
Power Dissipation 2 W
I/O map 9 input words
Fault Detection Broken wire (4 ... 20 mA mode) or under voltage
range (1 ... 5 V)


Voltage / Input
Operating Voltage (Channel toChannel) 30 VDC (max.)
Absolute Voltage (max.) 50 VDC
Linear Mesuring Range 1 ... 5 VDC
Input Impedance > 20 Mohms


Current / Input
Absolute Current (max.) 25 mA
Linear Measuring Range 4 ... 20 mA
Input Impedance 250 ohms + 0.003%



Resolution / Conversion
Resolution 12 bit
Absolute Accuracy Error @ 25 degrees C (voltage mode)
Typical: +/- 0.05% of full scale
Maximum: +/- 0.1% of full scale
Linearity +/- 0.04%
Accuracy drift with temperature Typical: +/- 0.0025% of full scale / degrees C
Maximum: +/- 0.005% of full scale / degrees C
Common Mode Rejection -72 dB @ 60 Hz
Input Filter Single pole low pass, -3 dB cutoff @ 15 Hz, +/-20%
Update Time 5 ms for all channels


Isolation
Channel to Bus 1000 VDC 3000 Vpp for 1 minute

  • Estimated Shipping Size
    Dimensions: 4" x 10" x 2" (10 cm x 25 cm x 5 cm)
    Weight: 0 lbs 11 oz (0.31 kg)



OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG-Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X-Emerson VE-,KJ-
Honeywell TC-,TK-GE Modules IC -
Fanuc motor A0-Yokogawa transmitter EJA-
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
Similar Products




Function
The 140 ACI 040 00 is a 16 channel analog input module which accepts mixed current inputs.


Illustration
The following figure shows the140 ACI 040 00 module and its components.





1 Model Number, Module Description, Color Code
2 LED Display
3 Fuse Cutouts
4 Field Wiring Terminal Strip
5 Removable Door
6 Customer Identification Label (Fold label and place it inside door)

Note: The field wiring terminal strip (Modicon #140 XTS 002 00) must be ordered separately. (The terminal strip includes the removable door and label.)



Wiring diagram for the 140 ACI 040 00 Module.







Notes on Wiring Diagram
The current sources are supplied by the user ( fusing is at the discretion of the user.)
A shielded cables must be used. In noisy environments twisted shielded cable is recommended. Shielded cable should have a shield tied to earth ground near the
signal source end.
Unused inputs may cause the activation of the F LED. To avoid this occurrence the unused channels should be configured in the 0 ... 25 mA range.
The maximum channel to channel working voltage cannot exceed 30 VDC.
N/C = Not connected
When field wiring the I/O module, the maximum wire size that should be used is1-14 AWG or 2-16 AWG; the minimum size is 20 AWG.



Resolution / Conversion
Resolution 0 ... 25,000 counts
0 ... 20,000 counts
0 ...16,000 counts
0 ... 4,095 counts
Absolute Accuracy Error @ 25 degreesC
+/- 0.125% of full scale
Linearity (0 to 60 degrees C) +/- 12 microA max., 4 ... 20 mA
+/- 6 microA max., 0 ... 25 mA
+/- 6 microA max., 0 ... 20 mA
+/- 6 microA max., 4 ... 20 mA
Accuracy drift with temperature Typical: +/- 0.0025% of full scale / degrees C
Maximum: +/- 0.005% of full scale / degrees C
Common Mode Rejection -90 dB @ 60 Hz
Input Filter Single pole low pass, -3 dB cutoff @ 34 Hz, +/-25%
Update Time 15 ms for all channels





    Parameter and Default values
    Name Default Value Options Description
    Mapping WORD (%IW-3X) -
    Inputs Starting Address 1 -
    Inputs Ending Address 9 -Task
    (Grayed if module in
    other than local)
    MAST FAST
    AUX0
    AUX1
    AUX2
    AUX3
    fixed toMAST if
    module in other thanlocal
    Module_Configuration
    Resolution 1.0 Deg 0.1 Deg
    Output Unit Centigrade Fahrenheit
    Value Type Temp Raw Value



    Notes on Specifications
    Absolute accuracy includes all errors from the internal CJC, TC – curvature, offset plus gain, for module temperature of 0 ... 60 degrees C. User supplied TC errors not included. z For Type J and K, add 1.5 degrees C inaccuracy for temperatures below -100 degrees C. z Type B cannot be used below 130 degrees C. z All TC ranges have an open TC detect and upscale output. This results in a reading of 7FFFh or 32767 decimal when an open TC is detected.
    Flat Addressing
    This module requires nine contiguous, 16-bit words—eight for input data and one for channel status. The data words formats are as follows.
    *A range warning is issued when a channel input exceeds the rated input value. Warning bit stay on after out of range bits are set. **An out-of-range bit is set when a channel input exceeds the rated input value by 2.4% or when a broken wire (4 ... 20 mA or 1 ... 5 V mode) is sensed on the channel. Out of range bits are also set if inputs drop below 0.5 V (1 ... 5 V mode) or 2.08 mA (4 ...20 mA mode)
    China 750 MA Bus Current Redundant Power Supply Module 140 CRP 932 00 supplier

    750 MA Bus Current Redundant Power Supply Module 140 CRP 932 00

    Inquiry Cart 0