Differential Scanning calorimeter (DSC)Oxygen Induction Time (OIT)

Brief introduction of the instrument:

The Differential scanning calorimetry (DSC) technique has been widely used. The differential scanning calorimeter is both a routine quality test tool and a research tool. Measmeasures the temperature, heat flow associated with the thermal transition inside the material. Our instrument is a heat flow type differential scanning calorimeter, with good repetition and high accuracy, which is especially suitable for accurate measurement of specific heat. The equipment is easy to calibrate, uses a low melting point, is fast and reliable, and has a very wide range of applications, especially in material research and development, performance testing and quality control. The properties of materials, such as glass transition temperature, cold crystallization, phase transition, melting, crystallization, product stability, curing / crosslinking, oxidation induction period, etc., are the research fields of differential scanning calorimetry, and different models are selected according to the experimental parameters and experimental requirements.

Instrument use:

Curing reaction temperature and thermal effect of polymer materials, material phase transition temperature and thermal effect measurement, crystallization of polymer materials, melting temperature and thermal effect measurement, glass transition temperature of polymer materials, etc.


Reference standard:

GB / T 19466.2 – 2004 / ISO 11357-2:1999 Part 2: Determination of glass transition temperature;

GB / T 19466.3 – 2004 / ISO 11357-3:1999 Part 3: Determination of melting and crystallization temperature and enthalpy;

GB / T 19466.6 - 2009 / ISO 11357-3: 1999 Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (kinetic OIT).

Technical parameter:

DSCDSC-100A Differential scanning calorimeters
DSC range0~±600mW
Temperature rangeRoom temperature~600℃
Heat-up rate0.1~100℃/min
Temperature resolution0.01℃
Temperature fluctuations±0.01℃
Temperature reproducibility±0.1℃
DSC accuracy0.001mW
DSC sensitivity0.01uW
Temperature control methodHeating up and constant temperature (automatic control of the whole program)
Curve scanHeating up the scan
Air controlThe instrument switches automatically
Display modeThe 24bit color 7-inch LCD touchscreen display is shown
Data interfaceStandard USB interface
Instrument standardsEquipped with standard substances (tin), the user can correct the temperature and thermal enthalpy
NoteAll technical indicators can be adjusted according to the user needs