ISO1167 Thermoplastics Pipes Internal Pressure Test For Conveyance Of Fluids Resistance

Brand Name:JINHAIHU
Certification:ISO 9001
Model Number:XGY-16B
Minimum Order Quantity:one set
Delivery Time:10 days after order
Payment Terms:T/T, L/C, D/A, D/P, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: No.1 North Road, Dongtumen, Jinhaihu Town, Pinggu District, Beijing, China
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

Thermoplastics pipes for the conveyance of fluids-Resistance to internal pressure-Test method


I. Function & Applications

XGY-16B Hydrostatic blasting tester is suitable for the determination of hydraulic instantaneous blasting and long-term constant pressure failure time of thermoplastic pipes for various fluid conveying plastic pipes. It is a necessary testing instrument for scientific research institutes, quality inspection departments and pipe manufacturers.

This series is the latest model, using microcomputer control technology, with test parameters set storage, display printing curve, real-time analysis, experimental report output and other functions.The software running Windows system. According to national standards, international standards or standards provided by users, the long-term hydrostatic performance and instantaneous blasting test of various pipes can be detected and judged, and the experimental data can be analyzed and processed, and the output can be printed.


II.Standards

GB/T6111-2018, GB/T15560-1995, GB/T18252-2008, GB/T18476—2001, ASTM D1598-2004, ASTMD1599, ISO1167, ISO13479, ISO9080, DIN EN 921 (1995-01), ASTM F1335


III. Technical data

Max.pressure16 MPa
Test stations2, 3, 4, 5, 6, 8, 10, 12 stations(can customize)
Control modecomputer and meter docuble control
Data preservationEach station has power off data protection function, boot can be restored
Timetiming time0~9999 h 59 min
Timing accuracy±0.1%
time resolution1s
Minimum Set Unitmin
PressurePressure control range0.2~10MPa
Pressure indicator unitsMPa,bar or PSI
Pressure control accuracy-1%~ +2%
Constant Voltage Control Precision of Full Load RangeWithin ±1%
Pressure display resolution0.001MPa,0.01bar or 1PSI
measuring range4%~100%FS
Allowable error limit for indicationWithin 1%

IV.Configuration

1.Pressure control system;
2.Pressure supply system;
3.Test tank and temperature control system;
4.End closures: φ10~500mm(according to customers requirement).

5.Refrigeration system(according to customers requirement)


Pressure control system

Constant-temperature tank



End caps


China ISO1167 Thermoplastics Pipes Internal Pressure Test For Conveyance Of Fluids Resistance supplier

ISO1167 Thermoplastics Pipes Internal Pressure Test For Conveyance Of Fluids Resistance

Inquiry Cart 0