Wastewater Electromagnetic Flow Meter Dn15 - 1200 With Rubber Ptfe Liner

Brand Name:Iflow
Certification:ISO9001, CE
Model Number:EMF-100-1
Minimum Order Quantity:1
Delivery Time:2-4 weeks
Payment Terms:T/T, L/C, D/P, Western Union
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Room 811-Building 143, No. 1399 Husong Road, Shanghai, China
Supplier`s last login times: within 32 hours
Product Details Company Profile
Product Details

Wastewater flow meter, magnetic flow transmitter, DN15-1200, Rubber liner

General description
The electromagnetic flow metering system, combining both a flow sensor and transmitter into one convenient package. It incorporates rugged carbon steel construction with flanges creating a versatile, user-friendly flow metering system for general purpose applications involving clean, sanitary, dirty, corrosive and abrasive liquids. The flow sensor is IP68 rated for protection from dust and low pressure water jets.

Technical advantages

1.Communication interface and protocol M-BUS or RS485
1.1 M-BUS interface:
Protocol: Basic Controls, EN1434, CJ188
Power supply : 1) built-in lithium battery power supply
2) M-BUS bus power supply + built in lithium battery
double power supply (optional)
1.2 RS485 interface:
Protocol: MODBUS RTU or BACnet MS/TP
Power supply: DC24V power supply + lithium battery
(optional)
2.Temperature range: (2 ~ 95ºC), temperature sensor
cable is: 1.5m (default) /3m (optional)
3.Protection grade: IP65, pressure grade: PN16
4.Accuracy:class 2
5.Flow range : 50:1 (default) or 100:1
6.Pipe section:Cast steel
7.Four independent periods of measurement, temperature threshold can be set,

Parameters

Product nameElectromagnetic flowmeter
Product typeLocal|compact displayRemote displaySignal converter
ModelIYF-EIYF-FIRT
Pipe Diameter (mm)DN10-DN2000
Power supply100-240 VAC / 18-36 VDC
Accuracy+ 0.5%+ 0.5%+ 0.5%
Power consumption<6w<6w<6w
Enclosure ratingIP65IP68IP65
Liquid temperature-25-120℃-25-120℃-25-120℃
Ambient temperature-25-50℃-25-50℃-25-50℃
Relative humidity10-90%10-90%10-90%
Meter ratio1:1001:1001:100
Flow directionBi-direction flowBi-direction flowBi-direction flow
CommunicationRS485 / BacnetRS485 / BacnetRS485 / Bacnet
Signal Output4-20mA/Pulse/Frequency4-20mA/Pulse/Frequency4-20mA/Pulse/Frequency


Measure Accuracy

Pipe Dia (mm)Velocity (m/s)Accuracy
3-20<0.3+ 0.25% FS
0.3-1+ 1.0% Readout
1-15+ 0.25% Readout
25-6000.1-0.3+ 0.25% FS
0.3-1+ 0.5% Readout
1-15+ 0.3% Readout
700-3000<0.3+ 0.25% FS
0.3-1+ 1.0% Readout
1-15+ 0.25% Readout