

Add to Cart
Power measurement method of IEC62087 audio and video equipment;
South Africa bias: SANS 941
On 23 July 2009, the European commission announced in its official
gazette (OJ) the implementation regulation (EC) No of ErP for
television sets, which took effect on 12 August 2009. The ordinance
mainly
The ecological design requirements (energy efficiency requirements)
of TV sets are stipulated, which are applicable to TV sets and
their monitors.
The energy efficiency of television sets involves four modes:
power-on, standby, power off and home. Power-on mode refers to the
state in which the TV is connected to the power source and
generates sound and images. Standby mode package
Includes reactivation and information/status display; Shutdown mode
refers to the state in which the device is connected to the main
power supply but does not provide any functions, including
providing only shutdown mode instructions or providing only
warranty
The state of the functions required by the EMC directive; Home mode
refers to the configuration of television sets for normal household
use recommended by the manufacturer.
1. The energy consumption of the power-on mode TV should not exceed
the limit shown in table 1. Where A refers to the viewable area in
square meters (dm2). Full High
Definition, FHD) resolution refers to a resolution of at least 1920
x 1080 pixels. Table 1 energy consumption limit (W) of eu for TV
boot mode was implemented on August 20, 2010
April 1, 2012 full hd resolution all other TV sets 20 + A * 1.12 *
+ A * + A * TV monitor 15 + A * 1.12 * +
A * + A * have spent
For standby and shutdown modes, the specific energy efficiency
limits are shown in table 2. Table 2 date of implementation of eu
energy requirements for standby and power off of TV sets
Power off on January 7, 2010 power off on August 20, 2011 energy
consumption of power off is 0.3w / 0.5-w * standby power
consumption is reactivated
Standby/other modes have automatic power off functions - monitors,
tuners and individual components are required - have * note: with
an easy to see switch, the easy to see switch means when the switch
is on
The energy consumption of the TV does not exceed 0.01 W when it is
turned off.
Since August 20, 2010, TV sets with the forced menu at the initial
activation shall provide "family mode" in the initial setting menu.
. The initial Settings menu here refers to a set of pre-set TV
Settings that the manufacturer has set up and that the user must
select at the initial activation time. If the user selects "home
mode" at the initial activation
The second selection procedure should be activated to determine the
selection.
Have spent The peak luminance ratio started on August 20, 2010: for
TVS without the initial set menu, the manufacturer delivered the
TVS when they were switched on
The peak brightness of the TV should not be less than 65% of the
peak brightness of the brightest starting state provided by the TV.
For TVS with an initial set menu, the peak brightness should not be
low in home mode
At 65% of the peak brightness of the brightest boot state provided
by the television.
5. Measurement methods on May 4, 2010, the European Union announced
the transitional measurement standards for implementing the
ecological design requirements for television sets. The measurement
standard of starting energy consumption is IEC
Version 2), standby and shutdown energy consumption measurement
method for EN version 1.
Contact person: Lydia
Mobile phone/WeChat :15099904126
QQ: 3003703237
Email address: lydia_yin@sina.cn
Company website: http://www.zkt-test.com
Address: 2H, building 1, science and technology innovation park, houting, sha jing, bao 'an district, shenzhen