5012-HD Diaper Permeability Tester for Absorption Rate Testing

Brand Name:Haida
Certification:CE、ISO
Model Number:5012-HD
Minimum Order Quantity:1 set
Delivery Time:20 days after order confirmed
Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Room 105, Building F4, District F, Tianan Digital City, Nancheng District, Dongguan City, Guangdong Province,China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

EQUIPMENT DETAILS OF 5012-HD DIAPER PERMEABILITY TESTER

5012-HD Diaper Permeability Tester for Absorption Rate Testing

APPLICATION

It is used to measure the permeation properties of diapers and diapers, such as the absorption rate, the amount of re-wet and the amount of leakage.

TEST STANDARD

GB/T 28004.1-2021 Diapers Part 1: Baby Diapers

GB/T 28004.2-2021 Diapers Part 2: Adult Diapers

INSTRUMENT CHARACTERISTICS

1. It can automatically complete the functions of adding liquid, constant pressure pressurization, timing and other functions in the test process, and measure the absorption performance indicators such as the pressure absorption rate, re-wet amount and leakage amount of the sample.

2. Touch screen control, Chinese and English menus, man-machine dialogue mode, easy to operate.

3. Built-in thermal printer, convenient to quickly print test results on site.

4. Professional computer analysis software can realize two-way operation with computer.

5. High-precision peristaltic pump to ensure the accuracy of penetrating liquid volume.

6. The built-in water tank is made of 316L stainless steel, which is durable and does not rust; automatic heating and constant temperature.

7. The test does not require manual addition of liquid, and one-button start of automatic liquid addition and automatic test.

8. The electrode is made of platinum, which has fast induction and durability.

9. It adopts stepping motor and high-precision ball screw drive, and the stroke control is accurate.

10. Automatic data processing, which can obtain the test average, standard deviation and coefficient of variation.

11. Equipped with a high-precision balance, and directly calculate the leakage and re-seepage after weighing.

12. Stainless steel weights are used to provide constant pressure; effectively avoid pressure changes after the sample absorbs water.

13. With buzzer reminder function.

TECHNICAL PARAMETERS

Technical Index

5012-HD

Accuracy of timing device

0.01s

Liquid addition device

Add liquid volume deviation ± 2mL, add liquid flow rate: 200 ~ 800mL/min

Liquid addition tank capacity

2L dosing volume

Baby Diapers

(40±2)ml/(60±2)ml/(80±2)ml

Baby disposable diaper

(30±2)ml/(40±2)ml/(50±2)ml

Adult Diapers

(100±2)ml/(150±2)ml

Adult disposable diaper

(70±2)ml/(100±2)ml

Hydraulic pressure strength

(2.0±0.2)kPa

Pressurized Pressure

(4.0±0.2)kPa

Standard Test Dosing Module

Baby

W

(80±1)mm(M1)

(85±1)mm(M2)

(95±1)mm(M3)

L

(100±1)mm(M1)

(108±1)mm(M2)

(125±1)mm(M3)

Adult

W

(70±1)mm(M1)

(95±1)mm(M2)

/

L

(170±1)mm(M1)

(170±1)mm(M2)

/

Standard test pressurization Module

Baby

W

(80±1)mm(Y1)

(85±1)mm(Y2)

(95±1)mm(Y3)

L

(100±1)mm(Y1)

(108±1)mm(Y2)

(125±1)mm(Y3)

Adult

W

(70±1)mm(Y1)

(95±1)mm(Y2)

/

L

(170±1)mm(Y1)

(170±1)mm(Y2)

/

Sample Base

Baby

U-shaped sample base

W

(122±1)mm(B1)

(135±1)mm(B2)

(152±1)mm(B3)

L

(125±1)mm(B1)

(136±1)mm(B2)

(154±1)mm(B3)

Adult

Curved sample base

319mmx200mm

Balance accuracy

0.01g, measuring range 300g

Machine size

820x575x750mm

Weight

62kg

Power Supply

AC220V 50Hz 100W