Add to Cart
This calibration device is designed in accordance with ASTM
D5207-03 and related IEC, UL, GB standards for measuring flame
temperatures in combustion test equipment.
Position the copper block 55±1mm above the needle flame burner.
Ignite the flame; the time for the copper block temperature to rise
from 100°C±2°C to 700°C±3°C must be 54±2 seconds to validate the
flame for testing.
Perform three measurements, allowing the copper block to cool
naturally to <50°C between tests.
ASTM D5207-03: Standard Practice for Confirmation of 20-mm (50-W)
and 125-mm (500-W) Test Flames for Small-Scale Burning Tests on
Plastic Materials. GB/T 5169.15: Fire Hazard Testing for Electric
and Electronic Products - Part 15: Test Flames - 500W Flame
Apparatus and Confirmational Test Methods.
IEC 60695-11-3: Fire hazard testing for electric and electronic
products - Part 11-3: Test flames - 500W flames - Apparatus and
confirmational test methods.
Model | 6015-HD |
Thermocouple | Armored K-type (NiCr/NiAl) fine-wire thermocouple with a 0.5mm diameter sheath. |
Timer | Adjustable range: 0.01-99.99 seconds |
Copper Block Specifications | |
Diameter | Ø9.00±0.01mm |
Length | 19.14±0.02mm |
Bevel Angle | 45±0.5° |
Mass (Pre-drilling) | 10.00g±0.05g |
Material | High-conductivity electrolytic copper |
Surface Finish | Fully polished |
Why choose us?
1.Design & Production : Solution Consultation for each order
Recommend the most cost -performance machine
Research & Develop the suitable one for Special- designed
Model.
2.Shipping & Delivery: One-Stop Service
Production- Deliver to your door - Installation & Training-
Technical Support
3.Warranty
1 year warranty with lifetime technology support
4.After-Sale Service
React within 2 Hours
Video inspection & on-site service combined
FAQ
Q: How about your warranty?
Q: What is the order process?
Q: Can we visit your factory before order?
Q: Do you accept customization service?