Add to Cart
Features
EKAC series air-cooled chiller (heat pump) units are highly
reliable,secure and flexible.
This series of units are elaborately designed to be delicate and
elegant. In addition, they can support fan coils and air handling
units of various specifications and models.
Units of this series are marked for their high efficiency, low
noise, user-friendliness, secure operation, easy installation and
maintenance etc, and are widely used in factories, stations,
hotels, villas, office buildings, top-grade residences etc.
Besides,they can also be used in industrial chilling.
EKAC460BR1LHV Air scroll chiller uses full DC frequency conversion
compressor, can achieve 15% ~ 100% stepless regulation, can
accurately adjust the unit capacity output according to the actual
load demand of the environment, part of the load output capacity is
sufficient, low energy consumption which more conducive to energy
saving.
EKAC series units feature leading-edge technologies and name-brand
accessories which are strictly tested for compatibility. Fully
hermetic volute compressor and low-noise fans minimize the
operation noise. With efficient volute compressors and precise
throttling systems with electronic expansion valves, the units
feature high EER and COP, especially at partial workload.
Units can be controlled individually or together by an electronic
controller. The controller is strongly interference proof and can
exert control from as far as 1000 meters away. Failures are
indicated by error codes displayed on the controller to facilitate
troubleshooting.
The units are designed to best facilitate installation. The cooling
system is made hermetic in the factory. Customers do not need to
connect any copper pipe or refill refrigerant. The water system has
an inlet connector which is to be connected to the terminal
equipment. Having installed the unit as instructed, customers just
need to check that water and pump pipes are clean before pumping
water and powering on the unit.
The controller defrosts the unit automatically according to the
operation time of the unit and the temperature of the heat
exchanger.
The cooling system is protected against extreme pressures:
discharge pressure will not be too high, nor will inhaling pressure
be too low; against extreme discharge temperature: discharge
temperature will not be too high; against freezing during cooling
operation: when the water temperature is too low, the plate heat
exchanger will not freeze up or burst internally; and against low
temperature: during cold winter time, the water pipe and plate heat
exchanger will not freeze up or burst internally (This feature
works only when the system is working in the heating mode with the
main power supply turned on).
The unit shell is made of galvanized, phosphorized steel plate with
pure polyester plating to withstand weathering. The unit is
reasonably designed to save space. It can be mounted on walls,
balconies or the roof, thus eliminating the need for a dedicated
equipment room.
The unit is highly adaptive and can operate smoothly in hostile
conditions such as extremely high or low temperatures.
To access and service any part of the unit, you just need to
dismantle the side panel or the front panel. When the unit stops
working abnormally, the controller prompts the reason to facilitate
troubleshooting.
Model | EKAC460BR1LHV | EKAC230CR1LHV | |||
Nominal cooling capacity | kW | 130.0 | 65 | ||
Nominal heating capacity | kW | 140.0 | 70 | ||
Total power of nominal cooling capacity | kW | 40.4 | 20.2 | ||
Nominal cooling operation current | A | 67.0 | 33 | ||
Total power of nominal heating capacity | kW | 40.0 | 20 | ||
Nominal heating operation current | A | 67.0 | 33 | ||
Unit max.operation power | kW | 52.0 | 26 | ||
Unit max.operation current | A | 91.5 | 45 | ||
COP | 3.22 | 3.22 | |||
IPLV | 4.35 | 4.35 | |||
Power supply | 380V/3N~/50Hz | ||||
Refrigerant Type | R410A | ||||
Compressor lubricant | POE 32-3MAF | ||||
Water side heat exchanger | Type | Efficient plate heat exchanger | |||
Water flow | Cooling | m³/h | 22.36 | 11.2 | |
Heating | 24.08 | 12 | |||
Water resistance | kPa | 50 | 38 | ||
Size of inlet/outlet water pipe connector recommended | DN80 | DN50 | |||
Fan type | Axial fan with broad impeller and low noise | ||||
Unit net weight | kg | 750 | 400 | ||
Unit operation weight | kg | 770 | 410 | ||
Dimensions | Length | mm | 2215 | 1110 | |
Width | mm | 1156 | 1156 | ||
Height | mm | 2335 | 2335 |
1. Working conditions for nominal cooling capacity: outlet water
temperature 7°C; water flow: 0.172m³/(h·kW); outdoor ambient
temperature 35°C.
2. Working conditions for nominal heating capacity: outlet water
temperature 45°C; water flow: 0.172 m³/(h·kW); outdoor dry/web bulb
temperature 7°C/6°C.
3. Water resistance includes water pressure drop of the unit and
the attached Y-shaped filter;
4. A maximum of 16 units can be connected to form a modular
combination.
5. Specifications are subject to change due to design variations
without further notice.