Applications of OPT SHR elight machine


1. Hair Removal
Remove unwanted hair from any part of the body.
2. Skin Rejuvenation
Removal or reduction of age spots, visible blood vessels, diffuse redness and uneven pigmentation while improving skin texture.
3. Thread Vein Removal
Removal or reduction of facila thread viens.
4. Acne Clearance
Reduction of inflammatory acne when used in combination with a topical cream or gel.
5. Vascular Lesions
Removal or reduction of port wine stains, thread veins and other vascular lesions.
6. Pigmented Lesions
Removal or reduction of freckles, age spots and other pigmented lesions.


Technical parameter of elight machine

Wavelength

430nm/530nm/560nm/590nm/640nm-1200nm

Handpiece number

2 piece with 5 filters

Spot size

12*30(mm) &15*50(mm)

Cooling system

semiconductor+air+water+cooling gel

IPL light energy

1-50(j/cm²)

Pulse duration

1-10ms

Pulse NO.

1-6

SHR pulse duration

1-7ms

SHR frequency

1-10HZ

SHR energy

1-50J/CM2

Skin cooling

-4°c-10°c

Display

10.4″color touch screen

Output power

2500W

Voltage

110v,50hz or 220v,60hz

Machine Size

(L*W*H):42cm*38cm*90cm

Net weight

60kg

Gross weight

91kg

Package size

69cm*64cm*102cm


Working Principal

OPT Technology
OPT is the use of cutting-edge intense pulsed light technology, belongs to the fourth generation of photonic technology. Perfect OPT (Optimal Pulse Technology) core technology, the use of three-dimensional technology concepts: energy + Pulse Width + pulse waveform. Due to changes the pattern of treatment light output, intense pulsed light is a revolutionary in the development, not only greatly improve the efficacy but also safety.

The important thing is that made a great improvement on hardware, its core is that can control each pulse precisely to let the energy of pulse apply to our skin without any reduction, eliminating the disadvantage of E-light and IPL first pulse’s high-energy peak value and the reduction of each sub-pulse energy. This makes OPT have a significant improvements on treatment efficiency and have a good function on improving skin texture, pore narrowing. Furthermore, it greatly improves the safety of treatment and avoids the side-effect of skin burns which often happened on photorejuvenation treatments. The smoothness and uniformity of the whole pulse energy’s output makes the efficiency of one time OPT treatment equal to 3-5 times traditional technology treatments. IPL technology experiences the brand-new breakthrough of four generations.



Hair removal of OPT elight machine


1. Cut or shave hair to 1-2mm or ask patients to shave at home 2-3 days before treatment.
2. Clear treatment area.
3. Turn on machine,
1). Use SHR, adjust pulse width at 7ms, frequency 5HZ, energy 10J/cm2.
2). Use normal hair removal treatment, put the 640nm or 690nm filter into the slot, select
"hair removal",adjust the parameter, set it to ‘ready’ .
4. Put cooling gel on treatment area about 2mm.
5. Wear protect goggles for patient and operator.
6. Shot the treatment area, let the crystal tip to touch cooling gel, You are permitted to have
1/3 overlapping on treatment area.
7. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area until heat disappear.
Skin rejuvenation

1. Clear treatment area.
2. Turn on machine ,put the 560nm filter into the slot, select "skin rejuvenation",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Pigmentation Therapy

1. Clear treatment area.
2. Turn on machine ,put the 480nm or 530nm filter into the slot, select "pigmentation
therapy",adjust the parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Vascular Therapy

1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "vascular therapy",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Acne Therapy

1. Clear treatment area.
2. Turn on machine ,put the 430nm filter into the slot, select "acne therapy",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.

Wrinkle removal

1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "wrinkle removal",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling