This product is used for absolute position detection of elevator cabins, achieving leveling without the need to encode floors or record floor numbers. The detection accuracy is higher, and the installation in the elevator shaft is not affected by environmental factors, making it simple to install and highly efficient.
4.4 Sensor Technology Data |
Measurement Principle | Absolute Distance Measurement |
Repeatability | ±1mm |
20System Accuracy at °C | ±(2mm+0.1mm×L[m]); L = Measurement Length (m) |
Basic Gauge Length | 6.6mm |
Sensor Housing Material | 6061 |
Lift Height | Max 34m |
Weight | ≈320g |
Power Supply Voltage | 10-30VDC |
Voltage Ripple | <200mVpp |
Input Current | Max 0.1A |
Interface | RS485/CAN |
Resolution | 0.1mm |
Operating Speed | Max 4m/s |
Storage Temperature | -30℃~100℃ |
Operating Temperature | -25℃~85℃ |
Humidity | 95%RH (Max); No Condensation |
Protection Level | IP54 (IP67 Customizable) |
4.5 Magnetic Scale Technology Data |
Model | AL-MS36 (1m~36m optional) |
Gauge Length | 6.6mm |
Operating Temperature | -25℃~85℃ |
Storage Temperature | -30℃~100℃ |
External Magnetic Field Strength | <70mT (otherwise magnetic encoding will be damaged) |
Precision at 20℃ (μm) | ±(2mm+0.1mm×L[m]); L = Measurement Length |
Carrier Material | 12Cr17Ni7 |
Thermal Expansion | ∆L[m]=L[m]×ɑ[1/K]×∆ ∂[K] (L=Magnetic Scale Length (m), ∆ ∂=Relative Temperature Change) |
Bending Radius | 50mm (Min) |
Usable Length | Max 36m |
Magnetic Scale Weight | ≈52g/m |
Protection Level | IP65 |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.