Construction: 8 x 19 Seale with steel-reinforced fiber core, regular lay,
Technical terms of delivery to DIN EN 12385, ISO 4344
Load-bearing wires in the outer strands: 152 Tensile grade 1570 N/mm², steel wire bright or galvanized
Add to Cart
Gustav Wolf Wire Rope With Steel-Reinforced Fiber Core For Elevators
For many years our elevator rope works standard PAWO F3 has a proven history in many types of traction elevator applications. The outer strands are designed in Seale construction. The 9 thicker wires of the outer strand layer offer a higher wear resistance.
The rope is primarily used where the service life is more defined by wear due to contact with the traction sheave than by rope fatigue due to bending. Deformations of the rope cross-section can be greatly reduced. The fiber content in the core of the steel wire rope works as a lubricant reservoir.
Properties
Construction: 8 x 19 Seale with steel-reinforced fiber core, regular lay,
Technical terms of delivery to DIN EN 12385, ISO 4344
Load-bearing wires in the outer strands: 152 Tensile grade 1570 N/mm², steel wire bright or galvanized
Rope Ø (permissible tolerance) | |
---|---|
no load: | with load (10% of Fmin) |
max. 3% < 10 mm | min. -1% <= 10 mm |
max. 2% > 10 mm | min. -1% > 10 mm |
rope diameter (mm) | calculated mass (kg/m) | min. breaking load (kN) | part-no. |
---|---|---|---|
8 | 0,243 | 38 | 761208040 |
9 | 0,307 | 48,3 | 761209033 |
10 | 0,385 | 60,5 | 761210034 |
11 | 0,465 | 73,4 | 761211033 |
12 | 0,546 | 86,8 | 761212033 |
13 | 0,65 | 103,1 | 761213033 |
14 | 0,752 | 119,3 | 761214033 |
15 | 0,867 | 137,6 | 761215033 |
16** | 0,981 | 154,8 | 761216033 |
18* | 1,226 | 193,6 | 761218033 |
19*** | 1,376 | 217,6 | 761219033 |
20* | 1,52 | 241,5 | 761220033 |
9.5 (3/8") | 0,346 | 54,4 | 761209533 |
12.7 (1/2") | 0,624 | 98,3 | 761212733 |
17.5 (11/16")* | 1,199 | 187 | 761217533 |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.