Step width | A | 600 | 800 | 1000 |
Exterior width | B | 1140 | 1340 | 1540 |
Construction Open width | C | 1200 | 1400 | 1600 |
Armrest center distance | D | 838 | 1038 | 1238 |
Floor slab opening | E | 1838 | 2038 | 2238 |
Support length | I | 1140 | 1340 | 1540 |
Traveling height H≤6m | Inclination a | 30° | 35° | |
a | 2198 | 2242 | ||
b | 1.732xH | 1.428xH | ||
c | 2567 | 2663 | ||
d | 4100 | 4300 | ||
e | 4000+1.735xS | 3300+1.428xS | ||
H1 | N/A | N/A | ||
L1 | N/A | N/A | ||
Traveling height 6m≤H≤9m | Inclination a | 30° | ||
a | 2688 | |||
b | 1.732xH | |||
c | 3057 | |||
d | 4900 | |||
e | 4000+1.732xS | |||
H1 | Mainly based on civil engineering drawings | |||
L1 | Mainly based on civil engineering drawings |
Technical Paraments
Escalator model | SN-TFJ |
Escalator speed | 0.5m/s |
Inclination | 30°/35° |
Traveling height | H |
Two beams span | L=a+b+c |
1.This drawing is based on the dimension mm. It applies to the
indoor installation with traveling height at or lower than 9m and
speed at 0.5m/s
2.When the step width=600mm, the upper truss should be extended for
417mm more.
3.When the traveling height is more than 7.8m, the upper truss
should be extended for 417mm more.
4.The driving power is Three Phase AC 380V,50hz.
5.When the leveling span is more than 15.0m, it needs a
intermediate support and lies in the middle.
6.When the escalator is installed in the second floor or above, the
pit will be canceled and the bottom and upper construction
structure will be balanced.
7.There should remain enough space in the escalator entry and exit.
The width should be at least 1238mm and the depth from the handrail
belt steering to the front barrier should be at least 2500mm.
8.The distance between the handrail center line and any barriers
cannot be lower than 500mm. The distance from the handrail belt
steering to the front barrier cannot be lower than 500mm.
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.