Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner

Brand Name:Macylab
Certification:CE ISO ROHS FCC FAD
Model Number:ICP-6800
Minimum Order Quantity:1pcs
Delivery Time:20-300days
Payment Terms:Western Union, MoneyGram, T/T, L/C
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: A-711, Haige International Building, Xuanwumen, Xicheng District, Beijing China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Inductively Coupled Plasma Optical Emission Spectrometer ICP-6800


Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.

At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.


Main features


Performance stability

The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.


Injection automation

Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.


Precision analysis

The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.


Quick test

In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.



Technical parameters


RFPower technical parameter


Circuit type

solid-state RF Power supply, with function of automatch

Frequercy

27.12MHz±0.05%

Frequency Stablity

<0.1%

Power Output

800W-1500W

Power Output Stability

<0.3%

Escaped RF radiation

30cm away from the instrument, electric fiekd: E<2Vtm

Sampling System Technical Parameter


Output working coil imer diameter

25mm

Torpue tube

Three concentric, extemal diameter 20mm

Coaxial nebulizer

Outer dameter 6mm

Double barrel atomizing chamber

Outer diameter 34mm


Gas Flow Controls


Plasma Argon Flowmeter

(100-1000)L/h(1.6-16L/min)

Auxiliary Argon Fiowmeter

(100-1000)L/h(0.16-1.6L/min)

Auxiliary Carrier Argon Flowmeter

(100-1000)L/h(0.16-1.6L/min)

Pressune Maintaining Value

(0-0.4MPa)

Cooling Water:Temperature

20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa


Spectrometer


Optics

Czerny-Turner type

Focal length

1000 mm

Grating

Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion

0.26nm/mm

Resolution

≤0.007nm(3600 line grating); ≤0.015nm(2400 line grating)

Wavelength range

3600 line grating:(190nm~500) nm; 2400 line grating:(190nm~800) nm

Minimum pace of stepping motor

≤0.0006 nm

Exit Slit

12μm

Entrance Slit

10μm


Photoelectric Converter Performance


Photomultiplier tube specification

R293/R928

Negative HV on PMT

0-1000V

Stability

<0.05%

Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):


ElementWL(nm)Limit ElementWL(nm)Limit
La408.672<3.0 Cr267.716<5.0
Ce413.765<5.0 Al396.152<5.0
Pr414.311<5.0 Zr343.823<5.0
Nd401.225<5.0 Ag328.068<3.0
Sm360.946<10.0 Sr407.771<1.0
Eu381.967<1.0 Au242.795<5.0
Gd342.247<10.0 Pt265.945<5.0
Tb350.917<3.0 Pd340.458<5.0
Dy353.170<3.0 Ir224.268<10.0
Ho345.600<3.0 Rh343.489<10.0
Er337.271<3.0 Ru240.272<5.0
Tm313.126<3.0 Ba455.403<1.0
Yb369.419<1.0 As228.812≤15
Lu261.541<3.0 Sb206.833≤15
Y371.030<1.0 Bi223.061≤10
Sc335.373<1.0 Hg253.652≤15
Ta226.230<5.0 Pb220.353≤15
Nb313.340<5.0 Ga294.364≤10
Mn257.610<3.0 Se203.985≤10
Mg279.553<1.0 Sn242.949≤20
B249.773<10.0 Te214.281≤10
Zn213.856<3.0 Ta226.230≤5.0
Co228.616<3.0 Th283.730≤10
Si251.611<10.0 Tl276.787≤30
Ni232.003<5.0 Re227.525≤5
Cd226.502<3.0 Ge209.426≤15
Fe239.562<3.0 Os225.585≤1
Ca393.366<1.0 W207.911≤10
Mo281.615<5.0 Cu324.754<3.0
V310.230<5.0 Li670.784≤3
Be313.041<1.0 Na588.995≤20
Ti334.941<3.0 K766.490≤60



Application Field

Certificate

Company profile

Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.


Exhibitions

China Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner supplier

Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner

Inquiry Cart 0