Add to Cart
Comprehensive Analyzing Tester of Non-load, Lode and Capability for Transformer
1.Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses. |
2.Harmonic test can be analyzed to 31 harmonics. |
3.Support Three Methods, two table method, two experimental methods. |
4.Do three-phase transformer no-load, load test, the instrument can automatically determine the wiring is correct, and shows three-phase voltage and current vector map. |
5.Single machine can do the following 100KVA distribution transformer full load current experiment; in one third of the rated current, complete 250KVA distribution transformer load the following test (in one third of the rated current, the instrument can be converted to load loss under rated current parameters, the machine is mainly used in the test bed with integrated supporting the use of transformers, the load characteristics to achieve high-precision transformer no-load test). |
6.All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so that more accurate test results. |
7.320x240 large screen, high brightness LCD display, full Chinese menu and operations to achieve prompt and friendly man-machine dialogue, touch buttons make the operation more convenient, wide LCD with brightness adjustment, can be adapted to the various summer and winter season. |
8.The instrument 40 can be preset by the user group is the test product parameters, and these parameters can be removed according to need and increase in use is very convenient. |
9.Comes with real-time clock, automatically recording test date, time, the preservation of favorable results, management. |
10.Panel-type thermal printer, the scene quickly print test results. |
11.Data (test sample set, the measurement results, the test of time, etc.) with power-down storage and browsing features, you can store 500 set of experimental results with computer on-line data transfer. |
12.Allows an external voltage transformer and current transformer for extended range of measurement, any measurable parameter is the test product. |
Comprehensive Analyzing Tester of Non-load, Lode and Capability for Transformer |
Current measurement range: 100mA ~ 60A, accuracy class 0.2; Voltage Range: 10V ~ 650V, accuracy class 0.2; External transformer can broaden the scope of measurement instruments; Frequency Range: 40 ~ 65Hz, accuracy class 0.2; Power Input: AC220V ± 10%; |
-----------------------------------
Contact : whhy818(@163..com) Name: Chloe Model HYKF transformer load and no-load test set
Wuhan huaying electric power tech & science co.,ltd
Address: 4F,Building 7,Optical Valley International Headquarters Industrial Park,No.62,Optical Valley Road,WUHAN,PR.CHINA
HYVA-405 CT PT test set HYVA-404 CT PT test set HYVA-402V CT PT test set HYBC-901 TTR HYRZ-902 Frequency response analyzer HYKF Load and no-load test set |
HYGK-307 Circuit breaker analyzer HYGK-306 Circuit breaker analyzer HYGK-303 Circuit breaker analyzer SLQ Primary current injection test set HYHL Contact resistance tester HYKZ-IV Vacuum degree tester |
HYGY Tan delta tester YJJ-II Insulating oil tester HYYJ-503 Insulating oil tester HYYJ-502A Insulating oil tester HYYJ-502 Insulating oil tester HYYJ-501 Insulating oil tester |
GTB AC dry hipot tester YDJZ AC DC oil hipot tester |
HYJB-PC6 Relay tester HYJB-PC Relay tester HYJB-III Relay tester |
HYXZ Frequency adjustable series resonance test se ZGF HV generator HYGS Tan delta tester FRC HV divider HYBL-II MOA arrester tester HYEC-10 Wireless phase tester |
HY2306 Insulation tester HY2305 Insulation tester HY2303 Insulation tester HY2553 Insulation tester HY2550 Insulation tester HYDW Grounding resistance tester HY2571-II Earth resistance tester |