1000Ah / 5hrs 36V Forklift Traction Battery Durable Environmentally Friendly

Brand Name:MYING
Certification:CE, TLC, ISO9001, ISO14001
Model Number:36V 1000Ah/5hrs
Minimum Order Quantity:1 group
Delivery Time:20
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Hong kong Hong kong China
Address: Room 1501(252), 15/F, SPA Centre, 53-55 Lockhart Road, Wanchai, Hong Kong
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

1000Ah / 5hrs 36V Forklift Traction Battery Durable Environmentally Friendly


TypeForklift Battery
ApplicationElectric Forklift Truck
StandardBS standard
Width of cell158mm
TechnologyTubular Positive Plates
Model36V 10DB1000
Cell Quantities18 cells
Cell Voltage2V
Connection TypeFlexible connection
Steel Tray SizeStandard or Customized

Product Catalogs --- BS standard
Type5hr. Capacity(Ah)

Overall Dimension

(mm)

Wet Weight

(kg)

Poles

Cell Volt

(v)

2DB20020045x158x622x6531322
3DB30030061x158x622x65318.122
4DB40040077x158x622x65323.322
5DB50050093x158x622x65328.42 or 42
6DB600600109x158x622x65333.62 or 42
7DB700700125x158x622x65338.82 or 42
8DB800800141x158x622x65344.542
9DB900900157x158x622x65349.642


Product Strength


1. High quality flooded lead acid battery

2. >= 1500 times cycle life.

3. High performance tubular positive plates

4. Meet IEC 60254 standard.

5. CE,ISO9001 and ISO14001.

6. Lower distilled water consumption
7. Environmental and healthy
8. Nice design and good quality
9. Easy to use and durable
10. Low current recharge
11. Competitive price
12. Wooden case packaging

13. Automatic watering syste and Argitation system.

14. Larger and thicker plate means less internal corrosion


Trouble Shooting


There are many reasons of the cells’ troubleshooting, except for the quantity and the storage, operating wrongly and unmerited maintenances are also one of the most important reasons.

If you find troubleshooting, analyze the reasons in time and take effective measures to eliminate it.

The features of the familiar troubleshooting and the reason and the methods of checking and repairing are as following:

1. Internal short-circuit

1.1 Symptoms

The charge voltage is always lower than normal; the discharge capacity is lower than normal; the discharge voltage quickly reduced to the final voltage; the voltage and the specific gravity raise slowly, and less or without gassing at the end of charge; the temperature of the electrolyte is high and raise faster during charge; the self-discharge is serious.

1.2 Probable causes

There are many reasons of short-circuit: conducting materials enter the cells connecting the positive and negative plates; the separator is damaged; the plates give birth to the lead bulb and store at the ear of the plates making short-circuit; the active materials are expanded or shed, the sediment touch the bottom of the plates leading short-circuit.

1.3 Possible remedy
First check if there are conducting materials entering the cells, if there are, remove the conductors. Remove the plates group checking if the lead-bulb expend leading short-circuit, if it is, remove the lead-bulb and change the electrolyte. If the separator is damaged, separate the plates group and find the damage one and change a new one.


2. The reversible vitriolic salt of the plates

2.1 Features

The discharge capacity is reduced and the specific gravity is lower than normal; during charge, the initial and the final voltage is higher than normal; the gassing appears too early and the temperature of the electrolyte raise fast and easy to exceed 55℃ ; voltage reduces too fast when discharge and reduces to the final voltage too early.

2.2 The reasons of troubleshooting

The cells are often weakly charged or not equalizing charged in time or often over-discharging or small-current discharging, in the station of half-discharging or discharging for a long time, or the level of the electrolyte is too low and some other reasons make the vitriolic lead in the positive and negative plates hard to transform into the active materials.

2.3 The ways to solve the problem

For the cells of plates with vitriolic salt, if it is not serious, you can revert by proper over-charging; for the serious ones, you can charge with small current; for the most serious ones, you can deal with them by using hydropath. In the sake of protecting from it, you should operate according to the service manual and take equalizing charge in time.

China 1000Ah / 5hrs 36V Forklift Traction Battery Durable Environmentally Friendly supplier

1000Ah / 5hrs 36V Forklift Traction Battery Durable Environmentally Friendly

Inquiry Cart 0