Model:JS-GD51

PRODUCT INTRODUCTION

This product is an indoor combustion gas detector with high stability , hereinafter called detector, used for combustion gas leak detection. It uses highly stable semiconductor gas sensor with features of stable performance and low drift of sensitivity. When it senses combustion gas leak that reaches the set alarm level, it will give out alarm sound with red LED flashing. The detector is applied in indoor places where combustion gas leaks possibly happen.

FEATURES
● Detects Natural Gas/LPG
● Celling Mounted
● Highly Stable Semiconductor Gas Sensor
● Adopts MCU Processing
● Manual Test/Auto Reset Functions
● Auto Check Malfunction
● High Capacity Relay (3A/250V)
● SMT Manufacture Technology, High Stability
● Comply to GB15322.2-2003


Model NO.

JS-GD51NS-AC

JS-GD51NVS-AC

JS-GD51LC-AC

JS-GD51NC-DC

JS-GD51LC-DC

Operating voltage

AC110V or 220V

DC12V-24V

Gas species

Natural gas or LPG

Sensor

Semiconductor

Drivable accessaries

N/A

Solenid valve

N/A

N/A

N/A

Alarm level

6%LEL(±3%LEL) of Natural gas

Alarm output

Sound & LED flash alarm

Sound level

≥75dB/m

Installation

Ceiling mounted

Working environment

-10℃~+50℃,(≤95%RH No congelation)

Dimension

Φ122*40mm

INSTALLATION

1. First identify your gas heavier or lighter than air. Heavier gases: LPG etc. Lighter gases: natural gas, marsh gas, artificial coal gas etc.
2. Choose a suitable installing position according to gas specific gravity. Detecting heavier gases, installation height 0.3-1.0m from floor , semi-diameter to gas source <1.5m; Detecting lighter gases, installation height 0.3-1.0m from ceiling, semi-diameter to gas source < 1.5m (refer to the following image).

3. Fix the attached base into a wall firmly with screws and hang the detector.
4. Do not make it close to gas stoves when installing at home in case it is roasted by flame. Neither places with heavy oil or smoke that may cause false alarms or block the gas convection holes and influence the detector sensitivity. Also it is can not be installed near to exhaust fans, windows, doors, and places with great vapor in bathrooms.

5. Connect the wires correctly according to the wire harness instructions. All wiring and installation must accord with the National and Local laws and criteria. Improper connection will cause the detector not alarm while gas leaking.

OPERATION INSTRUCTION

1. WIRING
Confirm the detector working voltage and output type by the label in the detector reverse.
DC type detector: 9-24V DC.
AC type detector: 220V AC.
A 5-PIN wire harness is attached in the gift box.
NOTICE:
The detector can not have Relay output and Pulse output for Solenoid valve simultaneously. Check the reverse label for the detector output type and pay attention to connect the wires correctly as per the connection instruction.

2. FUNCTION
2.1 Connecting the power, the power LED constant green on. fter the buzzer gives out a Di sound, the circuit enters into warm-up state. The red LED and yellow LED flash alternately during warm-up and stop in about 3 minutes, which indicates that the detector enters into normal working state. Test is forbidden during warm-up time.
2.2 When any combustion gas leak happens and reaches the alarm level, the alarm LED flashes red and meanwhile the buzzer gives out “Di...Di” sound. If the detector has output function, the relay output will be activated or pulse signal will be sent out to shut off the connected solenoid valves .
2.3 If an inside sensor failure occurs, the yellow LED constant on and the buzzer long beeps. Switch off the power and contact your dealer for maintenance. Do not take the detector apart privately to prevent electrical shocks.

3. TESTING
3.1 The detector has a self-test button for checking if the LED and the buzzer can work normally. When pressing the test
button, the red & yellow LED flashes alternately and the buzzer gives out alarm sound and the output is activated if with the function.
3.2 It is forbidden to test with a lighter directly toward the gas convection holes. This will cause damage to the inside sensor. Instead, gather the gas from the lighter into an empty plastic mineral water bottle and release the gathered gas toward the gas convection holes for testing.

FAILURE REASONS & SOLUTIONS

ALARM TREATMENTS

When the concentration of natural gas or LPG in ambient air reaches or exceeds the alarm level, the detector will enter into constant alarm state. Below treatments are advised:
1. Shut off pipe valves.
2. Do not plug or unplug electrical appliances.
3. Open windows to circulate air.
4. Inspect the gas leak reason and notify related departments in time to deal with the leak by professionals. If it turns out a false alarm, check if the installation position is improper.

NOTES

1. The detector is for combustion gases detection. It can not be used to test CO etc. poisonous gases.
2. Correct power supply must be provided and the wires must be connected right. It can not work without normal power supply.
3. Mild heat-up in housing surface is normal at working time.
4. Do maintenance as per this manual Periodically.
5. Vacuum the dirt in the detector surface every month.
6. Do not use cleansers or solvents to clean the detector. Chemicals may cause permanent damage or transient pollution to the sensor.
7. Do not spray air-freshers, hair gels, paints or other aerosols near the detector.
8. To assure the detector sensitivity, the detector should be inspected by a profession every year. If it fails to work, repair or replace the detector asap.
9. The service life of the detector semiconductor gas sensor is 5 years. Replace the detector immediately when the service life expires.
10. The detector can reduce accidents happening, but can not guarantee 100% safety. For your safety, besides proper usage of the detector, pay attention to build up safety conscious and take preventive measures in daily life.