l Conductor PVC/XLPE/PE Insulated 10KV 11KV ABC Cable High Voltage Overhead Aluminium conductor
Standards
ASTM B232 IEC BS DIN NFC 33-209 ISO9001-2008
Rated voltage
0.6/1kV 10kV 25kV 35kV
Nominal Cross-sectional Areas(sqmm)
10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2
Construction
Phase Conductor
Cables manufactured in bare aluminum, hard, class A stranding.
Insulation
Constituted by Thermoplastic(PE) or Thermoset(XLPE) polyethylene.
Neutral Conductor
The neutral conductor can be a bare aluminum cable(AAC) or an aluminum cable with steel core(ACSR).
Models and descriptions
Covered line wire:
JKY: Copper core PE insulated aerial cable
JKYJ: Copper core XLPE insulated aerial cable
Service drop cable:
JKLY: Aluminum core PE insulated aerial cable
JKLYJ: Aluminum core XLPE insulated aerial cable
Secondary UD cable:
JKLHY: Aluminum alloy core PE insulated aerial cable
JKLHYJ: Aluminum alloy core XLPE insulated aerial cable
Overhead Insulated Cable of Rated Voltage 10kV.
pe | Core | mm2 Main line core nominal area |
JKYJ,JKLYJ,JKLHYJ,JKLGYJ | 1 | 10~400 |
3 | 25~400 | |
3+k(A) 3+k(B) | 25~400,thereinto(K 25~120) | |
JKY,JKLY,JKLHY,JKLGY JKLYJ/Q,JKLHYJ/Q,JKLGYJ/Q JKLY/Q,JKLHY/Q,JKLGY/Q | 1 | 10~400 |
Applications
It is preferred to use of service drop (ABC cables) instead of
uninsulated conductors
at low voltage networks. service drop (ABC cables)are especially
used at areas
where the cost of underground networks is expensive and also
for electrification of rural areas like villages.
Technical Data
Maximum operating temperature 90 degree
Maximum short-circuit temperature 250 degree. Service drop( ABC
cables) are especially used at areas where the cost of underground
networks is expensive and also for electrification of rural areas
like villages.
ABC technical charaters based on Standard ASTM ANSI/ICEA S-76-474 and NFC 33-209
Standards
GB/T12527,1179 ,IEC60502 ,NFC 33-209 ,BS 7870 ,ANSI/ICEA S-76-474
AS/NZS 3560.1 etc.
*KAIQI POWER can also design and produce for special application
requirement.
PACKING AND SHIPPING
We are capable of meeting the most strict delivery schedules
according to per purchase order. Meeting the deadline is always the
top priority as any delay in the delivery of cable can contribute
to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils.
Cable ends are sealed with BOPP self adhesive tape and
non-hygroscopic sealing caps to protect the cable ends from
moisture. The required marking shall be printed with a
weather-proof material on the outsides of drum according to
customer's requirement.