Table of the voltage, cores and cross-section
Item | Category A ,B | 3.6/6kV | 6/10kV | 8.7/15kV | 12/20kV | 18/30kV | 21/35kV |
Category A ,B | 6/6kV | 8.7/10kV | 12/15kV | 18/20kV | - | 26/35kV | |
Single core | mm2 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 |
Three core | mm2 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 |
The cable with Category A rated voltage is used in the situation
requiring not over 1 min. of grounding fault lasting time. For the
cable with Category B rated voltage, the grounding fault lasting
time normally is not over 1 hour, max. lasting time is not over 8
hours, annual ground fault lasting time altogether should not be
over 125 hours, Category C includes all the system expect Category
A and B.
Applications
These power armoured cables are designed for open air installation,
for direct burrial underground, in water, in cable ducts, power
stations, where mechanical damages to the cable may occur.
Constructions
Conductor | Compact Stranded Copper Conductor, Class 2 as per IEC 60228 |
Circular solid Copper Conductor, Class 1 as per IEC 60228 | |
Flexible Stranded Copper Conductor, Class 5 as per IEC 60228 | |
Conductor Screen | Semi-conductor (MV only) |
Insulation | XLPE(Cross-linked polyethylene) |
Insulation Screen | Semi-conductor (MV only) |
Metalic Shield | Copper Tape Screen or Copper wire & copper tape Shield (MV must, LV optional) |
Filler | Fillers strip |
Wrapping Tape | Non woven wrapping tape or lsoh wrapping tape |
Inner Covering | Extruded PVC, or LSOH (MV only) |
Armour | Steel Tape Armour, Steel Wire or Aluminium Wire Armor optional |
Overall Sheath | PVC, FR-PVC, PE or LSOH |
Technical data
- Power cable according to DIN VDE 0276 part 603, HD 620, IEC
60502, BS 6622
- Temperature range max. to +90 °C
- Temperature during installation from 0 °C to +70 °C
- Short circuit temperature +250 °C (up to 5 seconds)
- Nominal voltage Uo/U 3,6/6 kV, 6/10 kV, 6,35/11 kV (dle BS),
18/30 kV, 19/33 kV (dle BS)
- Operating voltages 3,6/6 kV = max. 7,2 kV 6/10 kV = max. 12 kV
18/30 kV = max. 36 kV
- Test voltage a.c. 3,6/6 kV = 11 kV up to 5 min. 6/10 kV = 21 kV
up to 5 min. 18/30 kV = 63 kV up to 5 min.
- Minimum bending radius approx. 15 cable diameter
Test voltage | 6 / 10 kV | [kV] | 21 / 5 min. |
12 / 20 kV | [kV] | 42 / 5 min. | |
18 / 30 kV | [kV] | 63 / 5 min. | |
Temperature range | in motion | -5°C till +70°C | |
fixed | -20°C till +70°C | ||
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 15 |
Flammability | standard | EN 60332-1-2 |
We are capable of meeting the most strict delivery schedules
according to per purchase order. Meeting the deadline is always the
top priority as any delay in the delivery of cable can contribute
to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils.
Cable ends are sealed with BOPP self adhesive tape and
non-hygroscopic sealing caps to protect the cable ends from
moisture. The required marking shall be printed with a
weather-proof material on the outsides of drum according to
customer's requirement.
FAQ
1. Shipping: By sea or air due to heavy weight. Samples will be send by DHL,
Fedex. etc
2. Payment: We accept T/T, L/C , just choose what you like
3. Delivery time: Generally 7~10 working days upon receipt deposit. According to the
quantity.
4. MOQ: Generally our MOQ is 1000meters. samples below 20 centimeter can
be provided freely.
Our Services
♦ We are the one of biggest manufacture of electric wire and power
cable in China and has more than 20 years producing and marketing
experience.
♦ We accept OEM. The cable size and material are customized.Ur own
logo and own design are welcome. We will produce according to your
requirement and description;
♦ Please send us inquiry for more products info and we will give
you feedback in 12 hours.