CU / XLPE / PVC 0.6/1 kV fire retardant cable LSZH Power Cable For Buidings

Brand Name:SHANCABLE
Certification:KEMA,ISO,CE,IEC,PICC
Model Number:FRC CABLE 0.6/1kV
Minimum Order Quantity:1000meter
Delivery Time:7-15 days
Payment Terms:L/C, D/A
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Hunan China
Address: No.7577 Hunan Road, Pudong New District. Shanghai China
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

CU/XLPE/PVC 0.6/1kV Fire Retardant LSZH Power Cable For Buidings


Applications:


It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting. High voltage xlpe cable is used to be laid indoors, in tunnel, cable furrow or pipe, this cable couldn’t bear mechanical force outside. Laying single core cable in magnetic duct not permissible.


Standards:

International: IEC 60502, IEC 60228, (IEC 60332-3 for FR-type only)

China: GB/T 12706, (GB/T 18380-3 for FR-type only)

Other standards such as BS,DIN and ICEA upon request


Technical parameter


Cross section of conductorThickness of insulationThickness of SheathApprox.cable diameterMax.resistance of conductor at 20 ℃Test Voltage(AC)
mm2mmmmmmohm/kmKV/5min
5x2.50.81.813.67.413.5
5x41.01.816.14.613.5
5x61.01.817.73.083.5
5x101.01.821.01.833.5
5x161.01.823.81.153.5
5x251.21.828.70.733.5
5x351.21.932.00.5243.5
5x501.42.137.40.3873.5
5x701.42.241.70.2683.5
5x951.62.448.10.1933.5
5x1201.62.553.00.1533.5
5x1501.82.758.60.1243.5
5x1852.02.965.10.09913.5
5x2402.23.172.10.07543.5
5x3002.43.480.10.0603.5
5x4002.63.687.00.04703.5

Main Properties


No.Test ItemProperty
1ConstructionListed to the tables
2Conductor resistanceListed to the tables
3Test VoltageA.C 3.5kV 5minNo breaken
4Machenical Properties before agingTensile StrengthInsulationMin. 12.5N/mm2
SheathMin. 12.5N/mm2
Elongation at breakInsulationMin. 150%
SheathMin. 150%
Machenical properties after agingTensile StrengthInsulation100℃±2℃7days Min. 12.5N/mm2
Sheath100℃±2℃7days Min. 12.5N/mm2
Varying valve of tensile strengthInsulation100℃±2℃7days Max. 25%
Sheath100℃±2℃7days Max. 25%
Elongation at breakInsulation100℃±2℃7days Min.150%
Sheath100℃±2℃7days Min.150%
Varying valve of tensile strengthInsulation100℃±2℃7days Max. 25%
Sheath100℃±2℃7days Max. 25%
5Flame retardant propertyIEC60332 - 3
6Constant of insulation resistivityMin at 20℃36.7
Ki MΩ.kmMin at 70℃0.037

Working conditions:

1) This maximum working temperature of the conductor is 70°C.

2) During having a short(lasting less than 5 seconds)the maximum temperature of the cable conductor for shall not be above 160°C.

3) Environment temperature should be no lower than 0°C for laying the cable;

4) Bending radius allowance of the cable;

single core cable: no steel tape cable 20D: steel tape cable 15D.

3 core cable: no steel tape cable 15D; steel tape cable 12D.

China CU / XLPE / PVC 0.6/1 kV fire retardant cable LSZH Power Cable For Buidings supplier

CU / XLPE / PVC 0.6/1 kV fire retardant cable LSZH Power Cable For Buidings