Home /Power Cables /

Aluminium Stranded Bare Conductor Alloy Reinforced ACAR

Aluminium Stranded Bare Conductor Alloy Reinforced ACAR

Brand Name:SHANCABLE
Certification:IEC61089
Model Number:BC-ACAR
Minimum Order Quantity:10km
Delivery Time:15 Days or More
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Hunan China
Address: No.7577 Hunan Road, Pudong New District. Shanghai China
Supplier`s last login times: within 35 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Aluminium Stranded Bare Conductor Alloy-reinforced (ACAR) 16mm²~1250mm²


  • Place of Origin: Shanghai, China (Mainland)
  • Brand Name: SHANCABLE, OEM
  • Model Number: Overhead Conductor ACSR, AAC, AAAC, ACSS, AACSR, ACAR
  • Insulation Material: Bare conductor
  • Type: Overhead, Medium Voltage, High voltage, low voltage bare conductor
  • Application: Overhead, Overhead conductor Distribution Line and Transmission line
  • Conductor Material: aluminum or aluminium alloy, Aluminum, aluminium alloy, steel, carbon core
  • Jacket: Bare conductor
  • Productor name: Overhead Conductor ACSR AAC AAAC ACSR ACAR Bare Conductor
  • Insulation: Non-insulation bare conductor
  • Usage: State Grid, Power station, Transmission Line,overhead line
  • Standard: BS,ASTM,IEC
  • port of shipment: Shanghai
  • Certificates: ISO, CCC, KEMA
  • High Quality: PICC ensured

ACARIEC 61089
DiameterNumber of WirersAreaLinearRatedMax D.C. Resis-
Code NumberWireCond.Al.AlloyAl.AlloyTotalMassstrengthtance at 20℃
mmmmmmmmmm2mm2mm2kg/kmkNΩ/km
161.765.28439.737.3017.046.63.851.7896
252.206.604315.211.426.672.85.931.1453
402.788.354324.318.342.6116.59.250.7158
633.4910.54338.328.767.1183.514.380.4545
1004.4013.24360.845.6106291.222.520.2863
1252.9714.912783.348.6132362.727.790.2302
1603.3616.812710762.2169464.235.040.1798
2003.7618.812713377.8211580.343.130.1439
2504.2121.012716797.2264725.353.920.1151
2503.0421.31819131138269742.260.390.1154
3153.3423.430726361.3324892.660.520.0916
3153.4223.91819165174339935.176.090.0916
4003.7626.330733477.84111133.575.190.0721
4003.8527.018192102214311187.595.580.0721
4503.9927.930737587.64631275.284.590.0641
4504.0828.618192362494851335.9107.520.0641
5004.2129.430741797.35141416.993.980.0577
5004.3130.118192622775391484.3119.470.0577
5604.4531.23074671095761586.9105.260.0515
5603.4531.054750465.45701571.9101.540.0516
6303.7133.442194542056601820.0130.250.0458
6303.7934.124372714176881897.5160.190.0458
7103.9435.542195122327432051.2146.780.0407
7104.0236.224373054707752138.4180.530.0407
8004.1837.642195772618382311.2165.390.0361
8004.2738.424373445308732409.5203.410.0361
9004.4339.942196492949422600.1186.060.0321
9003.6640.254375673889552638.4199.540.0321
10003.8041.8721981621510322849.1190.940.0289
10003.8542.4543763043210612931.6221.710.0289
11204.0244.2721991424111553191.0213.850.0258
11204.0844.9543770548311893283.4248.320.0258
12504.2546.77219102026912893561.4238.680.0231
12504.3147.4543778753913273664.5277.140.0231
14004.5049.47219114330214443988.8267.320.0207






Application

The bare conductor:AAC,AAAC,ACSR,AACSR,ACAR and Galvanized steel wire, are used in overhead electrical power transmission and distribution lines with various grade voltage.

Construction: Bare aluminum alloy 1350-H19 wires, concentrically stranded around a Class A galvanized coated steel core wire. ACSR consists of a galvanized steel core of 1 wire, 7 wires, 19 wires etc. surrounded by concentric layers of aluminum wire.


Standards

Our Bare conductor can meet or exceedthe item of cable international standards, such as:IEC 61089, BS 215 part1(AAC), BS 215 part2, BS 324201 (AAAC), DIN 48201 part 5 (AAC), DIN 48204, ASTM B231(AAC), ASTM B232(ACSR), BS EN 50182, BS EN 50183(AAAC), GB/T 1179-2008. Also we accept the OEM and the new design cable as customers.


Specification

1. Aluminum conductor

2. Concentric-Lay-Stranded

3. Coated Steel Reinforced

4. ASTM,BS,CSA,DIN,IEC etc. Standards


Following the American Standards ( ASTM )

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes

B-231 Aluminum Conductors, Concentric-Lay-Stranded

B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)

B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)

B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

TypeDescriptionNo. of WireSection Area
(mm2)
AACAll Aluminum Conductor7~12716~1500
AAACAll Aluminum Alloy Conductor7~9117~1300
ACSRAluminum Conductors
Steel Reinforced
7~10316~1250
AACSRAluminum Alloy Conductors
Steel Reinforced
7~10316~1250
ACAR/AWAluminum Conductors
Aluminum Alloy Reinforced
7~10316~1250
ACSW/SAluminum Conductors
Aluminum Clad Steel Wire/Strand
7~10316~1250
GSWGalvanized Steel Wire3/2.64~37/4.5516.41~765.99
China Aluminium Stranded Bare Conductor Alloy Reinforced ACAR supplier

Aluminium Stranded Bare Conductor Alloy Reinforced ACAR

Inquiry Cart 0