XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32

Brand Name:SHANCABLE
Certification:ISO,CE,IEC,TUV,KEMA
Model Number:YJV32 MV 11kV
Minimum Order Quantity:Negotiable
Delivery Time:10 Days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Hunan China
Address: No.7577 Hunan Road, Pudong New District. Shanghai China
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32


Structure


1 ..... stranded bare copper
2 ..... inner layer of semi-conducting material
3 ..... core insulation of cross-linked polyethylene
4 ..... outer layer of semi-conducting material
5 ..... semi-conducting tape
6 ..... screen of copper wires

7 ..... Fillers strip, Yarn, or Paper
8 ..... Non woven Wrapping tape or Flame Retardant

9 ..... Extruded PVC Inner Covering

10 .... Galvanized Steel Tape Armoured
11 .... Overall Sheath: polyvinylchloride (PVC) or FR-PVC, PE, LSOH



Application


Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.

Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability.

Used in transformer stations, switching blocks, in electric power plants and industrial plants.

To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.


Standard


International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request


Specification


MV(6 to 35kv) Power Cable
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kVNo.of CoreConductor cross-section area(mm2)
xlpe insulation1 core 3 core10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm
Cu coreAl Core
YJV, N2XSY;PVC sheathed power cableYJLV, NA2XSY; PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cableYJLV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cableYJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable
pvc insulation
Cu CoreAl Core
VV(VY);PVC(PE)sheathed power cableVLV(VLY);PVC(PE)sheathed power cable
VV22(VV23);steel tape armoured,PVC(PE)sheathed power cableVLV22(VLV23);steel tape armoured,PVC(PE)sheathed power cable
VV32(VV33),VV42(VV43);steel wire armoured ,PVC(PE)sheathed power cableVLV32(VLV33),VLV42(VLV43);steel wire armoured ,PVC(PE)sheathed power cable


Technical data


Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

15 x cable O.D for single-core armoured cables

15 x cable O.D for multi-core non-armoured cables

12 x cable O.D for multi-core armoured cables



Certificate


ISO,CE, KEMA ,IEC, RoHS, CCC, P3C and more others at request


Ordering


Rated Voltage

Application Standard:IEC/BS/UL/GB

Number of Cores

Conductor Size $ Construction

Type of Insulation

Armored or unarmored. If armour, the armour type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement


Technical Parameter


Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulation ThicknessInner Sheath ThicknessDia. Of Armor WireSheath ThicknessApprox. O.D.Approx.WeightMax. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
mm2pc/mmmmmmmmmm(mm)kg/kmΩ /kmkV/5minIn air (A)In soil(A)
3 × 257/2.143.41.32.52.549.045790.72721120125
3 × 357/2.523.41.32.52.652.050970.52421140155
3 × 5010/2.523.41.42.52.754.058020.38721165180
3 × 7014/2.523.41.52.52.858.067880.26821210220
3 × 9519/2.523.41.52.52.962.078120.19321255265
3 × 12024/2.523.41.62.53.165.089290.15321290300
3 × 15030/2.523.41.72.53.268.0101250.12421330340
3 × 18537/2.523.41.73.153.372.0124030.099121375380
3 × 24048/2.523.41.83.153.578.0146460.075421435435
3 × 30061/2.523.41.93.153.783.0170140.060121495485

This product is applicable to the power transmission and distribution line with AC rated voltage(U0/U) of 3.6/6kV-26/36kV system.It is routed in air (cable bridge frame,indoor wall support,and tray) and soil(direct buried, cable trench,pipe ect.) respectively according to difference of the protection layer structure.

China XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32 supplier

XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32

Inquiry Cart 0