ZYD-T04 Laboratory Faucet, Shower hand, Plumbing hose, Angle valve Flow Testing Machine
Description:
Flow is a certain amount of time in a certain amount of time under a certain pressure, the common units are: L/min, that is, L. Americans commonly used GPM this flow unit, that is, gallons per minute, 1GPM=3.785L/min
Function:
1, flow and pressure can be adjusted;
2, the water temperature can be set, at room temperature to 90 C
range can be arbitrarily set;
3, can be carried out 0.01MPa low voltage flow test;
4, touch screen display water temperature, flow, pressure value
5, generation time flow curve;
6, print test results.
Applicable products: faucet, shower hand, hose, angle valve, flow rate is not greater
than 35L/min, the test pressure is less than 0.6MPa
Structure:
1, aluminum frame, flow test of water can be returned to the water
tank;
2, water supply: stainless steel water tank + stainless steel
multi-stage pump + pipe;
3, the pressure regulating part: the use of frequency converter to
adjust the output pressure and flow;
4, flow test part: electronic digital flow meter, respectively, to
detect the flow of cold water and hot water;
5, hot water tank: hot water tank installation of stainless steel
heating pipe, automatic heating temperature control, internal water
floating ball valve, drain pipe, overflow pipe, liquid level
switch, water temperature to 80;
6, cold water tank: can be connected with the cold water machine,
the internal water float valve, drain pipe, overflow pipe, liquid
level switch, etc.;
7, temperature detection: each station of the hot water, cold water
inlet pipe are installed temperature sensor, display the
temperature unit is C, the index value is 0.1;
8, control system: PLC+ touch screen control, touch screen will
show the flow of cold water and hot water, pressure and
temperature, with thermal printer
Remarks:
1. Faucet flow testing stadard of china and american are both using normal temperature cold water
2, the European standard EN 817 for hot and cold water inlet pipe
is respectively communicated with the cold water and hot water,
cold water, 34 degrees, 38 degrees Celsius, 44 DEG C and hot water
five temperature conditions in the detection of cold and hot water
inlet flow, total flow is cold and hot water inlet and.
3, Australia standard taps in the use of cold water at room
temperature were detected, the requirements of the first water 1
minute 500kPa, respectively in 150kPa, 250KPa and 350KPa several
pressure detection flow, maximum flow value and minimum value
difference of less than 2L / min.
4, hose flow test must be in a straight state, so the hose flow
test equipment to use the hydraulic characteristics of the test
machine for such a long time.
5, EN200 requirements under the pressure of 0.3MPa and 0.01MPa to
carry out the flow test.
6, American Standard ASME A112.18.1 test method: using cold water
for testing in 0.14 and 0.41MPa under pressure.
Installation conditions:
Venue:
1, a water inlet pipe and a drainage pipe, covers an area of about
4 square meters,
2 power: three-phase five wire, wire diameter 10m meters