CE6857E-48S6CQ-B Switch CloudEngine 6800 AC Power Supply

Brand Name:Huawei
Certification:CE
Model Number:CE6857E-48S6CQ-B
Minimum Order Quantity:1pc
Place of Origin:China
Price:US$1894/PC
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: 26Minyi Road, Xinqiao, Songjiang Industrail Zone Shanghai China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

CE6857E-48S6CQ-B Overview

CloudEngine 6800 is well suited to both the core and aggregation layers, and is fully compatible with CloudEngine 16800 and 12800 series switches, enabling enterprises to build scalable, simplified, open, and secure networks.

CE6857E-48S6CQ-B Specification

ItemDescription
Installation TypeCabinet Installation
CPU4-core, 1.6 GHz
MemoryDRAM: 4 GB
NOR Flash128 MB
SSD Flash8 GB
USBSupported
Power supply mode

· AC

· DC

· HVDC

Console portRJ45
Downlink Service interface48*10GE SFP+ (Note: The 10GE LRM/80KM linear optical module and 1000base-X auto-negotiation are not supported. 1GE optical modules can be used for interconnection only when auto-negotiation is disabled on the peer port.)
Uplink Service interface6*100GE QSFP28 (Note: 1. 100GE interfaces are compatible with 40GE; 2. 100GE interfaces do not support splitting into 4x25GE and 4x10GE.)
Service port supporting the stack function10GE optical ports and 100GE optical ports
RTCSupported
Typical power consumption [W]

· 148 W (50% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)

· 185 W (50% throughput, short-distance optical modules on all optical ports, dual power modules)

Typical heat dissipation [BTU/hour]

· 505 BTU/hour (50% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)

· 631 BTU/hour (50% throughput, short-distance optical modules on all optical ports, dual power modules)

Static power consumption [W]106 W
Static heat dissipation [BTU/hour]362 BTU/hour
Maximum power consumption [W]318 W
Maximum heat dissipation1085 BTU/hour
Number of power modules2
Redundant power supply1+1 backup
Rated input voltage [V]

· 600 W AC&240 V DC power module : AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC

· 1000 W DC power module : -48V DC to -60V DC

· 1200 W high-voltage DC power module: 240 V DC to 380V DC

Input voltage range [V]

· 600 W AC&240 V DC power module : AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC

· 1000 W DC power module : -38.4 V DC to -72 V DC

· 1200 W high-voltage DC power module: 190 V DC to 400 V DC

Maximum input current [A]

· 600 W AC&240 V DC power module : 8 A (100 V AC to 240 V AC); 4 A (240 V DC)

· 1000 W DC power module : 30 A (-48 V DC to -60 V DC)

· 1200 W high-voltage DC power module: 8 A

Rated output power [W]

· 600 W AC&240 V DC power module : 600 W

· 1000 W DC power module : 1000 W

· 1200 W high-voltage DC power module: 1200 W

Certification

· Safety standards compliance

· EMC standards compliance

· Environmental standards compliance

Power supply surge protection [kV]

· AC: 6 kV in common mode and 6 kV in differential mode

· DC: 4 kV in common mode and 2 kV in differential mode

· HVDC: 4 kV in common mode and 2 kV in differential mode

Types of fansPluggable
Number of fans4
Redundant fansThe device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation modeAir cooling
Airflow directionPort-side intake or exhaust, depending on the fan modules and power modules.
Availability0.9999961836
MTBF [year]49.35 years
MTTR [hour]1.65 hours
Noise at normal temperature (27°C, sound pressure) [dB(A)]

· Front-to-back airflow: average 50 dBA (maximum: 54 dBA)

· Back-to-front airflow: average 53 dBA (maximum: 57 dBA)

Noise at high temperature (40°C, sound pressure) [dB(A)]

· Front-to-back airflow: average 69 dBA (maximum: 73 dBA)

· Back-to-front airflow: average 72 dBA (maximum: 77 dBA)

Long-term operating altitude [m (ft.)]≤ 5000 m (16404 ft.)
Long-term operating relative humidity [RH]5% RH to 95% RH, noncondensing
Long-term operating temperature [°C (°F)]0°C to 40°C (32°F to 104°F) at an altitude of 0 to 1800 m (0 to 5906 ft.)
Storage altitude [m (ft.)]< 5000 m (16404 ft.)
Storage relative humidity [RH]5% RH to 95% RH, noncondensing
Storage temperature [°C (°F)]-40°C to +70°C (-40°F to +158°F)

China CE6857E-48S6CQ-B Switch CloudEngine 6800 AC Power Supply supplier

CE6857E-48S6CQ-B Switch CloudEngine 6800 AC Power Supply

Inquiry Cart 0