Twin And Earth Cable

Brand Name:Zion communication OR OEM
Certification:CE, RoHS, VDE, UL, CUL, LPCB
Model Number:Twin And Earth Cable
Minimum Order Quantity:20 KM
Delivery Time:25 working days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Hangzhou Zhejiang China
Address: NO.68,HUAQIAO ROAD, LIN'AN, HANGZHOU, ZHEJIANG, CHINA
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details
Twin And Earth Cable

Twin And Earth Cable

Twin And Earth Cable

Application: Cable Standards:
This cable has a bare protective conductor
plus 1, 2 or 3 cores.
Used for fixed installations in dry or
damp premises clipped direct to surface,
on trays or in free air.
Where mechanical protection is required,
it can be laid in conduit or trunking.
BSEN 50363-3, BS 6004
Flame Retardant according to IEC/EN 60332-1-2
Product Description:
Conductor RE: 1mm² to 2.5mm²: Class 1 solid copper
RM: 4mm² to 16mm²: Class 2 stranded copper
Circuit Protection
Conductor (Earth)
1mm² to 2.5mm²: Class 1 solid copper
4mm² to 16mm²: Class 2 stranded copper
Insulation Polyvinyl Chloride (PVC)
Sheath Polyvinyl Chloride (PVC)
Characteristics:
Voltage Rating Uo/U 300/500V
Temperature Rating -5°C to +70°C
Minimum Bending Radius Fixed: 6 x overall diameter
Core Identification:
1 Core: Brown
2 Core: Brown Blue
2 Core: Brown Blue
3 Core: Brown Blue Black
Should not be installed at temperatures below 0°C or above +60°C
Dimensions:
Zion Code No. Of
Cores
Nominal Cross Sectional Area(mm²) Nominal Thickness
Of Insulation
(mm)
Nominal overall
diameter
(mm)
Nominal overall
diameter
(mm)
Nominal overall
diameter
(mm)
Nominal overall
diameter
(mm)
Nominal
Weight
Kg/km
TAEC2x1.0 2 1 1 1 0.6 0.9 4.35 x 7.95 68
TAEC2x1.5 2 1.5 1 1 0.7 0.9 4.85 x 8.90 87
TAEC2x2.5 2 2.5 1 1.5 0.8 1 5.65 x 10.65 120
TAEC2x4.0 2 4 2 1.5 0.8 1 6.30x 11.95 172
TAEC2x6.0 2 6 2 2.5 0.8 1.1 7.10x 13.70 235
TAEC2x10 2 10 2 4* 1 1.2 8.70x 17.25 373
TAEC2x16 2 16 2 6* 1 1.3 9.85 x 20.0 530
TAEC3x1.0 3 1 1 1 0,6 0.9 4.35 x 9.80 91
TAEC3x1.5 3 1.5 1 1 0.7 0.9 4.85 x 11.2 115
Conductors:
Nominal Cross Sectional Area
(mm²)
MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
ohms/km
Plain Wires
1 18.1
1.5 12.1
2.5 7.41
Class 2 Stranded Conductors for Single Core and Multi-Core Cables
Nominal Cross Sectional Area (mm²) Current Carrying Capacity Amps MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
ohms/km
Annealed Copper Conductor
Circular Plain Wires
4 7 4.61
6 7 3.08
10 7 1.83
16 7 1.15
The above table is in accordance with EN 60228
China Twin And Earth Cable supplier

Twin And Earth Cable

Inquiry Cart 0