Home /Communication Equipment /

4 Core 1.00mm2 Shielded FRLS Fire Resistant Cable for Installation in Fire System

4 Core 1.00mm2 Shielded FRLS Fire Resistant Cable for Installation in Fire System

Brand Name:Zion communication OR OEM
Certification:CE, RoHS, VDE, UL, CUL, LPCB
Model Number:Fire Resistant Cable Shielded 1.00mm2
Minimum Order Quantity:20 KM
Delivery Time:25 working days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Hangzhou Zhejiang China
Address: NO.68,HUAQIAO ROAD, LIN'AN, HANGZHOU, ZHEJIANG, CHINA
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

4 Core 1.00mm2 Shielded FRLS Fire Resistant Cable for Installation in Fire System


Quick Detail:


  • Fire Resistant Cable
  • FRLS Shielded 1.00mm2
  • Bare Copper Conductor
  • Silicone Rubber Insulation
  • PET / AL-Foil
  • Fire Resistance Low Smoke PVC
  • 100M, 200M, Plastic Spool, Carton
  • 180 Minutes under Fire of 750 Degrees without Short-Circuit.
  • MOQ: 20 KM

Description:


KT1440 FRLS Shielded 1.00mm2 Fire Resistant Cable Bare Copper Silicone Insulation

is a specific type of fire alarm cable Produced by Zion communication. These cables are used for

installation in fire systems for connecting fire alarms etc. The cable can be installed

in dry and moist areas as well for fixed open air installation. This cable type with

electrostatic screening (St) protects the transmission circuits against extern-electrical

interferences. And all these cables comply to:

IEC60331-23-2003

IEC60332-3-22-2005

IEC61034-2-2005

EC60754-1-99

IEC60754-2-99

IEC60331-21:1999

BS EN 61034-2:2005

BS 7629-1:2008

BS EN 50267-2-1:1999


Zion communication using best raw material and best worker to produce KT1440 FRLS Shielded 1.00mm2 Fire Resistant Cable Bare Copper Silicone Insulation to meet high performance in practical application.

KT1440 FRLS Shielded 1.00mm2 Fire Resistant Cable Bare Copper Silicone Insulation is packed in

200m Spool, 2 Spools in Carton, then will be layed on pallet to protect the spool and easier carry. Because of good managing methods, Zion communication’S price of FRLS Shielded 1.00mm2

Fire Resistant Cable Bare Copper Silicone Insulation is not high although our quality is really high.


Applications:


These cables are used for installation in fire systems for connecting fire alarms etc.

The cable can be installed in dry and moist areas as well for fixed open air installation.

This cable type with electrostatic screening (St) protects the transmission circuits

against extern-electrical interferences.


KT1440 FRLS Shielded 1.00mm2 Fire Resistant Cable Bare Copper Silicone Insulation
APPLICATION:

These cables are used for installation in fire systems for connecting fire alarms etc.

The cable can be installed in dry and moist areasas well for fixed open air installation.

This cable type with electrostatic screening (St) protects the transmission circuits

against externelectrical interferences.

Standards:
IEC60331-23-2003
IEC61034-2-2005
IEC60754-2-99
IEC60332-3-22-2005
IEC60754-1-99
IEC60331-21:1999
BS 7629-1:2008
BS EN 61034-2:2005
BS EN 50267-2-1:1999
Fire Testing:
180 minutes under fire of 750 degrees without short-circuit.
ELECTRICAL DATA (AT20OC)

Minimum

Bend

Radius

Min.Insulation

resistance

Max.Working
Temperature

Test voltage

(rms value)

Max.

Operating

voltage

peak value

MΩ/kmVV
8×Diameter200-15℃~+90℃1000300/500
TYPES AND MECHANICAL DATA

Types

sqmm

(mm2)

ConductorInsulation

Shielded1/

Drain Wire /

Shielded2

Level of

twisting

Jacket

Matterial

OD of

Jacket

(mm)

1×2×1.001×2×1.07 BCSiliconePET/TC/AL-FoilFRLS6.50
2×2×1.002×2×1.07 BCSiliconePET/TC/AL-FoilFRLS7.50
*NotesClass 1: SolidClass 5: Flexible
Order Informations:
Marking

Zion communication KT1440 FRLS Shielded n×2×1.00MM2 CABLE

Package100M, 200M, Plastic Spool, Carton, Pallet

Competitive Advantage:


1, From raw materials to final products, we perform intense quality checks to maintain our product quality:

A, Incoming material inspected by QC.

B, Manufacturing Process Control

C: Workers trained daily/weekly/monthly

D: Work instructions manual at each work station

E: 5S system implemented

F: Machine maintenance procedure

G: Quality Control and Final Inspection

The QC staff will check the material, process product

and final product according to the specification or test procedure.


2, Our R&D efforts center on reinforcing and developing element technologies

needed to support the future growth and success for customers and Zion communication.

3, We know customers have urgent needs.

We are skilled at effective communication to interact with customers.

In order to provide prompt service, we can answer for you 7*24 hours.

4, We can Quickly and professionally answer for the inquire

5, More than 1000 kinds of cable, connectors and assembles can be produce and organized from us

6, Intime delivery


China 4 Core 1.00mm2 Shielded FRLS Fire Resistant Cable for Installation in Fire System supplier

4 Core 1.00mm2 Shielded FRLS Fire Resistant Cable for Installation in Fire System

Inquiry Cart 0