SERVO-I MAQUET VENTILATOR 6487180 Battery for Compatible Medical Equipment Batteries
The SERVO-i ventilator by Maquet (Getinge) uses an internal battery system to provide power backup in case of a power failure or for patient transport. Here are some key details about the battery (part number 6487180):
SERVO-i Ventilator Battery (6487180) Specifications
Battery Type: Rechargeable Lithium-Ion (Li-Ion)
Voltage: Typically 11.1V
Capacity: Around 5.8Ah (varies by model and version)
Battery Life: Provides up to 3 hours of operation per fully charged
battery. The ventilator can hold two batteries, extending the
operation time to approximately 6 hours.
Charging Time: Usually takes 2-3 hours to fully charge.
Hot-Swappable: The battery is hot-swappable, meaning it can be
replaced without interrupting ventilation.
Replacement & Maintenance
Replacement Interval: Batteries should be replaced every 2–3 years
or as per the ventilator’s battery test results.
Charging Method: The batteries charge automatically when the
ventilator is plugged into AC power.
Testing: The ventilator performs automatic battery diagnostics, but
manual testing can be done through the system menu.
The **SERVO-i MAQUET Ventilator 6487180** is a widely used
mechanical ventilator in critical care settings. Over time, the
ventilator's battery may need replacement due to reduced capacity
or failure. Here’s what you need to know about the battery for the
SERVO-i MAQUET Ventilator (Part Number 6487180):
---
### **Key Information About the SERVO-i MAQUET Ventilator
Battery:**
1. **Part Number**: 6487180
- This is the official part number for the battery used in the
SERVO-i MAQUET Ventilator.
2. **Battery Type**: Rechargeable Lithium-Ion Battery
- Designed to provide backup power to the ventilator during
transport or power outages.
3. **Purpose**:
- Ensures uninterrupted ventilation during patient transport or in
case of AC power failure.
- Typically provides several hours of operation, depending on usage
and settings.
4. **Compatibility**:
- Specifically designed for the SERVO-i MAQUET Ventilator series.
- Ensure compatibility with your specific ventilator model before
purchasing.
5. **Installation**:
- The battery is user-replaceable and typically located in a
compartment on the ventilator.
- Follow the manufacturer’s guidelines for safe removal and
installation.
6. **Maintenance**:
- Regularly check the battery health and charge level through the
ventilator’s diagnostics or battery status indicator.
- Replace the battery if it no longer holds a charge or fails to
meet performance standards.
---
2. **Medical Equipment Suppliers**:
- Reputable suppliers of medical equipment and parts often carry
compatible batteries.
3. **Online Marketplaces**:
- Be cautious when purchasing from third-party sellers to avoid
counterfeit or low-quality batteries.
---
### **Tips for Battery Replacement:**
- **Verify Compatibility**: Double-check the part number (6487180)
and ensure it matches your ventilator model.
- **Follow Safety Guidelines**: Always power off the ventilator
before replacing the battery.
- **Dispose of Old Batteries Properly**: Recycle the old battery
according to local regulations for lithium-ion batteries.
---
### **Troubleshooting Battery Issues:**
- **Battery Not Charging**: Check the charging cable, power source,
and battery compartment for damage.
- **Short Battery Life**: The battery may need replacement if it no
longer holds a charge.
- **Error Messages**: Refer to the ventilator’s user manual or
contact technical support for error codes related to the battery.