BIFMA X5.1 Office Chairs Base / Caster Durability Test Equipment
Bifma X5.1 Office Chairs Base / Caster Durability test machine
Introduction of product:
Bifma X5.1 Office Chairs Base / Caster Durability test machine is
suitable for testing the base seat chair with caster, to determine
the ability of caster or base resistance to fatigue and abrasion
caused by moving forward or backward. Place the caster specimens on
the tester platform, and loading 102kg to make the specimen in
repeat travel at a certain speed, the travel distance should be at
least 762mm...After certain times, check the caster function is
normal. This machine is required to place on a horizontal and
stable platform when install. Slip type life tester needs to
connect with 7kgf/cm^2 or above clean gas supply.
Technical parameters of Bifma X5.1 Office Chairs Base / Caster
Durability test machine:
Test bed size | 85x160cm |
Test speed | 10± 2/min |
Test stroke | ≥ 762mm |
Load | 102kg± 1g |
Blocks thickness | 3.2mm, width 51mm, edge blend 3 pcs |
Test times barrier: | 2000 times; Barrier free: 98000 times |
Counting | 0~999 999 adjustable |
Control mode | PLC+TEXT screen control |
Size(WxDxH) Test machine: | 270x85x129cm; |
Weight(Kg) | 500kg |
Air supply | 7kgf/cm^2 and above stable gas source |
Power A | 1 AC 220V 3 |
Standard:
BIFMA X5.1 Caster/Chair Base Durability Test - Cyclic