GNS1 4P 50KA Low Voltage Power surge protector with direct lightning protection

Brand Name:SINGI
Certification:CE/CB/ISO9001/CCC
Model Number:SPD
Minimum Order Quantity:500pcs
Delivery Time:normally 15 days after deposit
Payment Terms:T/T,L/C,Western union
Contact Now

Add to Cart

Active Member
Address: NO.161 JINGQI ROAD YUEQING ECONOMIC DEVELOPMENT ZONE, YUEQING,ZHEJIANG,CHINA
Supplier`s last login times: within 31 hours
Product Details Company Profile
Product Details

GNS1 4P 50KA Low Voltage Power surge protector with direct lightning protection


APPLICATION


The SPD normally is installed in the building power distribution box, computer center,telecom room, elevator control room, wiring tv room, building control room, security monitor center, fire control center ,industry control room, frequency converter equipment control room, hospital surgery room, monitoring room and the distribution box in whichelectronic mechanical equipment.


COMPONENTS INSTRODUCTION


  • Invalid tripping device

There is invalid tripping device on the protector modular, when the protector is invalid cause of over thermal, breakdown, the invalid tripping device can separate from the power grid automatically and the indication signal is sent out. When the protector is normal, the green is displayed ,when invalid tripping ,red is displayed.


  • Alarming apparatus

The alarming apparatus is power supplied by 220VAC,the indication lamp is green when the protector work normally, normal open contact is closed and the normal closed contact is open. Audio light alarming function: when the protection modular is invalid , the alarm will be beeping ,the normal green lamp will be changed into red lamp at the same time. When the maintainer press the stop button, the buzz will stop ,but the red lamp still is on, if the fault is not solved within 24 hours, the alarming apparatus will send out beep once again.


  • Remote signal contact

The protector can be with remote signal contact, the contact is normal open, if one or moremodular of protector is invalid, the contact will be closed and send out fault signal. The rated parameter of remote signal contact isA C36V,1A.

emDC SURGE PROTECTIVE DEVICE
CodeFSP-D40
Pole2P3P
Voltage500VDC,600VDC800VDC,900VDC,1000VDC
In(8/20)us(KA)20KA
Imax(8/20)us(KA)40KA
StandardIEC/EN61643
TypeII
Characteristic CurveB,C,D
Working Temperature“-5°”to +40°
Protection DegreeIP20
Electrical lifeMore than 8000times
Mechanical lifeMore than 2000times
Dimension(W)X(H)X(D)36x90x6854x90x68
Installation35MM DIN RAIL
AccessoryRemote signal
Installation Altitude≤2000M



China GNS1 4P 50KA Low Voltage Power surge protector with direct lightning protection supplier

GNS1 4P 50KA Low Voltage Power surge protector with direct lightning protection

Inquiry Cart 0