Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output

Brand Name:Merrytek
Certification:CE, UKCA, UN38.3,MSDS
Model Number:KE028-02AM180HE
Minimum Order Quantity:100
Delivery Time:1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit.
Payment Terms:T/T or Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 101-1101, Building 17, Dianda Guyuan Industrial Park, Mashantou Community, Matan Street, Guangming District, Shenzhen
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output


1. Description


1) Constant power output LED emergency power supply with a wide output voltage range.
2) Input relay switching.
3) High safety, high performance, long life LifePO4 battery.
4) With battery management.

5) Manual check and self-check selection.


2. Parameters

Charge PartKE02802AM180HE03AM180HE04AM180HE05AM180HE
Rated input voltage220-240Vac 50Hz/60Hz
Rated input current0.06A Max. @230Vac
Input inrush current10A(Twidth=100us 50% Ipeak )@230Vac(Cold start at full load )
Power factor≥0.5@230Vac
Input power<4W@230Vac
Battery charging current200mA200mA350mA350mA
Battery charging time24 hours Max.
Emergency PartOperating modeEmergency mode
Load typeLED
Emergency power2W2.5W4W5W
Emergency time3hours
Load output current25-10mA31-12mA50-20mA57-23mA
Load output voltage80-200Vdc
BatteryLifePO4 (The battery capacity meets the emergency time at 25℃)6.4V 1.8Ah6.4V 1.8Ah6.4V 3.6Ah6.4V 3.6Ah
Battery warrantyWarranty 5 years @5~60℃.
Exception Driver RequirementsSurge current8A
Input current3A Max.
Output current2A Max.
LED Indication
(Manual test)
ChargingGreen light
FaultGreen light off
Emergency Function TestManual testDefault
Auto testSettable
Auto TestingFault/test / StatusReasonCharge Indicator Status
The battery is fully charged and operationalStandard daily use
solid green
Battery ChargingInitial Charge/Battery Top Up
Flashing green 1 sec on 1 sec off
Auto Test 3 Hours (every 12 months)Periodic self-test
Flashing Green 3 sec on 1 sec off
Auto Test 5 Min (every 30 days)Periodic self-test
Flashing Green 3 sec on 3 sec off
Duration test faultAutomatic test failed
Flashing Red 0.5 sec on 0.5 sec off
LED faultNot plugged in or damaged/faulty
Flashing Red 2 sec on – 2 sec off
Battery Disconnected/FaultyNot plugged in or damaged/faulty
solid red
Emergency protectionBattery over-charge/deep discharge protectionYes
Output over-voltage protectionYes
Output overload protectionYes
Output short circuit protectionYes

Operating

Environment

Operating temperature/humidity0℃…+50℃, Humidity: 20%-75%(without condensation)
Storage temperature/humidity-5℃-35℃
Case Max. Temp(Tc)75℃

Safety

& EMC


Withstand voltage3000Vac 5mA 60s (Input “L N” – output “SEC+ SEC-)
Safety standardEN61347-1, 60598-2-22, 61347-2-7, 62034
EMC standardEN55015, EN61000-3-2, EN61000-3-3
Battery standardUN38.3
Environmental protection requirementsCompliant with RoHS
CertificationCE
OthersInput/output(terminal/wiring) specificationPress terminal, wire diameter: 0.5-0.75mm2
IP ratingIP20
Type of protectionClass 2
Installation typeBuilt-in installation
Installation dimension146*30*22.5mm
Packaging requirementWhite box+Instruction manual+clapboard+outer carton(K=A)
Weight75g (driver)
Lifespan5 Year @Ta

Notes:

All parameters are tested on the input voltage 230Vac, environment temperature 25℃, unless otherwise specified.


3. Dimension (Unit: mm)


4. Battery Dimension (Unit: mm)

Fig. A Fig. B

Fig. C Fig. D


5. Wiring Diagram


OR


6. Manual and Automatic Test Set Exchange


7. Wire Preparation

1)Solid or Stranded wire type: 0.5 -0.75mm2

2)To access or remove the wires from the terminals, use a screwdriver to push the buttons down


8. Manual Test & Operation Instructions

1) Before installation, set Pin short: Manual Test.

2) Connect the wire according to the wiring diagram.

3) L, N power on, Switch on S1. Then the load lamp turns on, the emergency driver indicator light turns green, emergency power supply is normal charging. Turn off Switch S1, and the load lamp turns off.

4) Emergency Simulation: Switch on, the load lamp turns on, press the switch(TEST SWITCH), then switch to emergency mode, the indicator light of the emergency driver will be extinguished. Release the switch(TEST SWITCH), then the lamp is powered by the LED driver, and the indicator light will turn on.


9. Automatic Test & Operation Instructions

1) Before installation, set Pin open: Automatic Test.

2) Connect the wire according to the wiring diagram. Remove the test switch on the LED Emergency Driver.

3) L, N power on, start the clock, and periodic self-test. To replace the battery, turn off the power supply, and Re-time.


10. Battery Application Notice

1) The battery should be recharged and discharged semiannually in normal use conditions.

2) Do not connect to the circuit when the battery is not in use to prevent over-discharge of the battery due to self-consumption of the circuit board.

3) Please keep the battery away from the heat source when installing and using it, and only allow it to be used in a certain working temperature range.

4) The battery should be stored in a cool and dry environment.

5) After long-term storage, the battery is cycled every 12 months as required.

6) AC power is off, and the clock lasts for 7 days. Power on and re-time. To replace the battery, turn off the power supply, and Re-time.


China Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output supplier

Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output

Inquiry Cart 0