MC090S U2 Microwave Motion Sensor Free ISM Band 5.8ghz Microwave Band Active Detection IP20

Brand Name:Merrytek
Certification:UL FCC
Model Number:MC090S U2
Minimum Order Quantity:100PCS
Delivery Time:1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit.
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 101-1101, Building 17, Dianda Guyuan Industrial Park, Mashantou Community, Matan Street, Guangming District, Shenzhen
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods


1.Feature

  • Special motion sensor for sterilizing lamp: the light turn off when detect people come; the light turn on when people leave.
  • Free ISM band 5.8ghz microwave band, active detection, stable and reliable.
  • Ultra-small installation size, multiple installation methods (surface and bottom screw installation)
  • Batch products to ensure compliance with FCC certification requirements, the lamp with sensor certification is guaranteed.

2.Parameters


InputOperating Voltage Range100-305VAC 50/60Hz
DC Input VoltageN/A
Rated Voltage120-277VAC 50/60Hz
No-load Power≤1.2W
Stand-by Power≤0.5W
Surge TestBetween L and N: 1KV
OutputWorking ModeON/OFF
Type of LoadResistive or Capacitive
Load Capacity800W (Resistive) or 400W (Capacitive)
Current of LoadN/A
Load surge current30A relay - 30A (test twidth 500us @230Vac at 50% Ipeak, cold start at full load) or 60A (test twidth 200us @230Vac at 50% Ipeak, cold start at full load)
Interface1-10V dimmerN/A
Synchronization control interfaceN/A
High and Low Level InterfaceN/A
PWM control interfaceN/A
Interface terminal wiring modeN/A
SensorOperating Frequency5.8 GHz ±74.9 MHz.ISM wave band
Transmitting power0.5mW Max.
Delay time5S/30S/60S/3min/5min/10min/20min/30min
Hold time15min/30min/60min/120min//+∞
DIM downN/A
Cut offN/A
Detection Area100% / 75% / 50% / 25%
Hold time 2(sterilizing time)15min/30Min/60Min/120Min/+∞
Daylight on/offN/A
Detecting Radius4-7m(mounting height 3m )
Mounting Height2.5-6 m(Suction Top Installation)
Detecting AngleCeiling mount 150°
Wireless moduleOperating FrequencyN/A
Transmitting powerN/A
transmission distanceN/A
modulation modeN/A
Coding group numberN/A

Operating

Environment

Operating Temperature-20℃…+60℃ Humidity: 85% (non-condensing)
Storage Temperature-40℃…+80℃
Certificate StandardsSafety (LVD)standardsEN61058-1,EN61058-1-2
EMC standardsEN55015,EN61547,EN61000-3-2,EN61000-3-3
Environmental RequirementRoHS
CertificateUL FCC
OthersInput/output terminal specifications0.5-0.75mm2
IP RatingIP20
Protection ClassClass II
InstallationBuilt-in installation
Dimension62*36*25mm
PackageBubble bag + partition + outer box (K=A)
Net Weight36g
Lifetime5 years warranty@Ta 230V full load

Note

1. “N/A”means not available.

2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s.

3.Function
on/off function

4. Dimension (mm)


5. Wiring


6. Structure


7. Radiation Pattern

Ceiling mounting

Ceiling mounted height: 3m

Sensitivity: 100%/75%/50%/25%

Ceiling mounted height: 6m(*)

Sensitivity:100%/75%/50%

Normal moving (Speed:1m/s)

Normal moving (Speed:1m/s)

Slow moving (Speed 0.3m/s)

Slow moving (Speed: 0.3m/s)

* 50%,75%,100% detection sensitivity is workable when installed at 6 m mounting height. Only 25% sensitivity is not able to detect motion signal.


Wall mounting

Wall mounted height: 2m

Sensitivity: 100%/75%/50%/25%

Normal moving (Speed:1m/s)

Slow moving (Speed 0.3m/s)


8. Function Dialing Settings

Detection Area

12

ONON100%

ON

-

75%

-

ON50%

-

-

25%

Delay Time

345
ONONON5S
ONON-30S
ON-ON1min
IVON--3min
V-ONON5min
VI-ON-10min
VII--ON20min
VIII---+∞

Hold Time

678
ONONON15min
ONON-30min
-ON-1H
VON--2H
IV---+∞
9. Initialization

Attachment:

1>. Self-test: there is no output of self-test on power (12S). After self-test 2 seconds detection. The sterilization light was turn on when no one trigger the sensor ,No output when the detect human body was moving, and the sterilization light was on after the pre-set delay time when the human being left.

2>. Delay time: after the human being left, the pre set delay time enter into the hold time (the sterilizing time).

3>.Hold time: The time of the sterilization light on, the hold time has the interrupt function, the hold time (the sterilization light is on), when the human being came ,the light will be turn off, after the human being leaves,the sensor get into the delay time, after run the delay time, the sterilization light will be turn on. The hold time will not start the timer from the beginning, it will continue to account the time base on previous lighting time, until the pre set hold time finished ,then the light off, need to power again after the restart.


10. Factory settings

Detection Area: 100%, Delay Time: 5S, Hold Time2: +∞


11. Use Caution

1. Be sure to cut off the power supply before installing or adjusting the setting of the dial switch.

2. The microwave cannot pass through the metal, make sure there are no metal above the sensor.

3. It has to be at least 15mm away from metal around the microwave antenna. It is not allowed to place antenna and metal on the same horizontal.

China MC090S U2 Microwave Motion Sensor Free ISM Band 5.8ghz Microwave Band Active Detection IP20 supplier

MC090S U2 Microwave Motion Sensor Free ISM Band 5.8ghz Microwave Band Active Detection IP20

Inquiry Cart 0