Add to Cart
12-24V DC Motion Sensor MSA001D, independent flush mounting, with silent reed switch relays
1. Features
1) Use patented 5.8GHz Low Impedance Microwave Antenna,anti
wireless interference, such as Wi-Fi, Bluetooth, 5G etc.
2) Parameters can be set by DIP switch.
3) Compact size for Independent flush mounting.
4) Silent reed switch relays for some special application.
2. Function
This product is a dry contact motion sensor developed for the IoT
sensing market. P1-P2 (please refer to spec) is a normally open
relay, when the sensor detects human, the switch is closed. When
the sensor detects no one in the environment, the relay will be
disconnected after a preset hold time. So that the presence
detectors system can identify whether there are people in the
environment according to the state of this switch.
3. Initialization
After first power on, the light turns on and closes after 10
seconds. During the initialization, sensor is not able to detect
moving objects signal.
4. Factory Settings
Detection Area: 100% Hold Time: 5s Daylight Sensor: Disable
5. Application Notice
1) The sensor should be installed by a professional electrician.
Please disconnect the power before installing, wiring or changing
the setting of the DIP switch.
2) Put the sensor as far as possible from large areas of metal
plate, glass and other materials with high medium density to avoid
triggering by mistake.
3) Avoid using objects that have been vibrating for a long time
around the sensor, such as shaking fans, etc. The vibration signal
will be regarded as the motion signal to trigger the sensor.
4) Avoid the detection window of the daylight sensor of the
detector irradiated by an invalid light source, which will
interfere with the measurement of ambient light.
5) The sensor should be installed at least 2 meters away from the
wireless router.
6) Sensor’s microwave can penetrate wall of building. It may cause
misreport when microwave penetrates wall to detect the moving
objects outside fortified area. To avoid triggering by mistake,
choose suitable place when installing, keep away from glass,
plasterboard, wooden wall and other things that microwave can
easily penetrate and choose appropriate sensing parameters
according to
space, for examples:
A. When product is used in the room whose length and width is about
2m or less, detecting area should be set to 25% (application
scenario: washroom, sitting room )
B. When product is used in the room whose length and width is about
3m, detecting area should be set to 50% (application scenario:
washroom, hallway, sitting room )
C. When product is used in the room whose length and width is about
4m, detecting area should be set to 75% (application scenario:
small office, meeting room, library )
D. When product is used in the room whose length and width is about
5m or more, detecting area should be set to 100% (application
scenario: large office, meeting room, library )
Note: The setting detecting area depends on the actual environment
(detecting area parameters