Add to Cart
Hot Runner Manifold Tubular Heater For Injection Molding Machine
Description
Hot Runner Manifold Tubular Heater also known as Formed Tubular
Heaters or Flexible heaters, these heaters are mainly used for
heating hot-runner manifolds for injection-molding plastics. The
tubular heater can be precisely press-fitted into a milled slot or
manually hammered in with a plastic hammer and without special
tools. By taking into account the recommended slot dimensions, a
contact surface of up to 75 percent can be achieved for optimum
heat transfer — for both round and square formats.
A superior grade of helical wound high temperature resistant NiCr
alloy heating wire is swaged in Chrome Nickel Steel sheathed tubes.
The insulation consists of superior grade of magnesium oxide (MgO).
Threaded terminal post which gives a cold section of approx 40mm
(min) are sealed with special sealing components to prevent the
heater from moisture. These are then formed to shapes as required
to press fit in the hotrunner manifold which dissipated even heat
transfer to the hotrunner mould.
For manufacturing manifold tubular heaters it is necessary to
provide an accurate dimensional sketch showing all centre
distances, bending radius and path.
Specification
Length | 300 -1550mm | 400 - 2100mm |
Maximum Current | 12 A | 15 A |
Nominal Voltage | < 230V | < 400V |
Wattage | ±10% | ±10% |
Dielectric Strength | 1.5 HV | 1.5 HV |
Insulation MΩ | >5Ω | >5Ω |
Leakage Current | <0.5 mA | <0.5 mA |
Minimum Unheated | 30mm | 35mm |
Terminal Pins | M3 x .50mm/ Plain post | M4 x .70mm |
Length Tolerances: ± 2% |
Feature
Available in Chrome Nickel Steel.
Available in Dia 8.5mm, 6.5mm & Square Section 6mm x
6mm,8mmx8mm.
Sealed Edges to prevent from Moisture.
Superior Grade Magnesium Oxide Insulation.
Swaged for Good Electrical Insulation & Even Heat. Transfer.
Application
Hot Runner Manifolds