RO Water Filtration System Part Small Diaphragm Plastic Solenoid Valve Coil

Brand Name:BRANDO
Certification:None
Model Number:BB08330538
Minimum Order Quantity:1000
Delivery Time:Negotiation
Payment Terms:T/T, PayPal, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang China
Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

RO Water Filtration System Part Small Diaphragm Plastic Solenoid Valve Coil


Applicable Industries:Solenoid Valve
Type:Fittings
Place of Origin:Zhejiang, China
Brand Name:Brando
Hole Size:8.3mm
Height:30.5mm
Width:34.0mm
Voltage:AC24-240V (50Hz/60Hz), DC12-48V
Power:5W
Insulation class:F
Protection class:IP65, IP67, IP68
Applications:Water Filtration System, Water Purification System, Domestic RO System

Dimension of Plastic Solenoid Valve Coil :

Technical Data:

Model
BB08330538
Hole size
8.3mm
Height
30.5mm
Width
34.0mm
Voltages
AC24-240V (50Hz/60Hz), DC12-48V
Power
5W
Insulation class
F
Application examples
Water Filtration System, Water Purification System, Domestic RO System, Small RO Water Treatment System

Details:

Hole size 8.3mmHeight 30.5mmWidth 34.0mm


Solenoid Coil Production Line:



Attention:
1. This air suspension compressor pump solenoid coil is made of high quality components.

2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.


Why does a coil get burnt when removed from valve?

This is because with AC 50/60Hz coils you are reducing the impedance or resistance of the coil, as the shading ring within the armature or stem generates resistance within the coil. By removing the coil whilst powered the resistance is reduced thus the power consumption can easily increase above the coil winding class limits causing over heating.


Steps and methods for properly installing a solenoid valve coil:

1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.

2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.

3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.

4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.

5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.

6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.

7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.


Focus on your demands, Offer you best solution:


√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing


Welcome to your any question and inquiry!

China RO Water Filtration System Part Small Diaphragm Plastic Solenoid Valve Coil supplier

RO Water Filtration System Part Small Diaphragm Plastic Solenoid Valve Coil

Inquiry Cart 0