Add to Cart
2 1/2 Inch Joil Type Pulse Valve Diaphragm made of Nitrile Rubber
1. Solenoid coil has one-touch terminal block with easy electrical
wiring. For outdoor use, use aluminum die-casting material body.
2. A timer controller for quick opening and closing of valve and a
waterproofed, up to 180'C heat resistance coil are used.
3. Used for dusting off the surface of the FILTER BAG.
4. Diaphragm is opened by the movement of solenoid coil,
instantly(0.1~0.9sec) large amounts of compressed air is discharged
at once.
The diaphragm repair kits we have many in store, it will be sent
out ASAP if we have received the payments.
If you need a large quantity, we can give a big discount for you.
Welcome your inquiry.
Note: the Viton ( for high temperature performance ) material is
also available.
Joil Diaphragm repair kits | |||
Type | Quantity | Suitable valve | Material |
1" | 1 | JICI25, JICR25, JISI25, JISR25 | Nitril or Viton |
1 1/2" | 1 | JICI40, JICR40, JISI40, JISR40 | |
1 1/2" | 2 | JICI40, JICR40, JISI40, JISR40 | |
2" | 2 | JISI50, JISR50 | |
2 1/2" | 2 | JISI65, JISR65 | |
3" | 2 | JISI80, JISR80, JIHI80, JIHR80 |
Installation in Pulse Valve,Application in Industrial Dust Collector System
We guarantee offer you the superior quality products with competitive prices
Installation of Joil type pulse valve diaphragm
1. To avoid any potential operational problems it is preferable
that the valves are not mounted underneath the tank where
condensation may collect. All o-rings should be coated with a
silicone based lubricant or similar.
2. Dresser nut seals where used are a pressure seal only, not a
structural component. Do not rely on dresser seals to retain either
the tanks or blowtubes. Tanks and blowtubes must be independently
restrained.
3. Connect to Goyen pilot valve, if remotely actuated.
4. Ensure compressed air supply is dry and free from oil and dirt.
5. Check all cleaning system components are secure before applying
pressure.
6. Apply moderate pressure and check for leaks.
7.Fully pressurise system.
8.Test fire and listen for proper actuation and crisp pulse noises.
Technical requirements for pulse valve diaphragm:
Due to pulse valve diaphragm needs from time to time opening and closing action is a flexible mechanism to control the air circulation, has good flexibility and requirements, also demanded the sealing as high as possible, so the pulse valve diaphragm material is directly related to the service life of pulse valve diaphragm and using effect, in other words, the pulse valve diaphragm is good or bad will directly affect the working stability of pulse bag filter soot cleaning system, is directly related to the use of dust removal equipment cost, general pulse valve diaphragm has the commitment, the number of service life or actions using high-quality pulse valve diaphragm can directly reduce the cost of the use of dust removal equipment.
If you want to know more,pls contact us without any hesitation