Type | Quantity | Suitable valve | Material |
1" | 1 | JICI25,JICR25,JISI25,JISR25 |
Nitrile or Viton |
1 1/2" | 2 | JICI40,JICR40,JISI40,JISR40 |
2" | 2 | JISI50,JISR50 |
2 1/2" | 2 | JISI65,JISR65 |
3" | 2 | JISI80,JISR80,JIHI80,JIHR80 |
Diaphragm installation in Pulse Dust Valve,application in pulse
blowing system,bag dust filtration system
About Failure and repair of diaphragm
1. The spring is damaged. The spring on the pulse valve spool is
easily damaged. The appearance is that the pulse valve is deflated
to the blow port for a long time. The treatment method is to
replace the spring.
2. The rubber pad is damaged. After the use time is long, the
rubber pad on the pulse valve spool is easily damaged. The
appearance is that the pulse valve is deflated to the blowing port
for a long time. The treatment method is to replace the rubber pad.
3, the valve core dirt, because the intake air is not clean,
causing the fouling of the valve core, resulting in the appearance
of long-term intake of the nozzle or the pulse valve does not work
after the power, the treatment method is to clean the valve core.
4, the diaphragm is damaged, after long-term work, the diaphragm is
easy to fatigue, oxidation, etc., resulting in the appearance of
long-term deflation of the pressure relief port, the pulse valve
does not work, the treatment is to replace the diaphragm.
5. The orifice is blocked or damaged. The intake air is not clean
and the throttle hole is blocked. The appearance is that the pulse
valve is deflated to the nozzle for a long time. The treatment
method is to clean the orifice; the orifice is damaged or missing,
and the orifice is made. Loss of interception, resulting in
abnormal pressure relief, the appearance of the pulse valve after
the power is activated, the pressure relief port deflation, but the
pulse valve is not sprayed, the treatment is a replacement orifice.